GE GXSF27E manual Opena Nearby Soft Water Faucet, For correct water softening system

Page 15
—OPEN A NEARBY SOFT WATER FAUCET—

GEAppliances.com

Service: Manually Initiated Electronics Diagnostics

1.To enter diagnostics, press and hold the MODE button until (000 – –) shows in the display.

A The first 3 digits indicate water meter operation as follows:

000 (steady) = soft water not in use…no flow through the meter.

Turbine Switches

For correct water softening system OR Manual background

Water

Switch (B)

Meter (A)

 

C While in this diagnostic screen, the following information

is available and may be beneficial for various reasons.

This information is retained by the computer from the

first time electrical power is applied to the control.

Press and hold the UP button to display the number

of days this control has had electrical power applied.

Press and hold the DOWN button to display the

number of regenerations initiated by this control

—OPEN A NEARBY SOFT WATER FAUCET—

000 to 199 (continual) = repeats display for each gallon of water passing through the meter.

Manual backgroundManual background Motor

Position Manual background

switch

Sensor

Manual backgroundManual backgroundManual background housing Manual backgroundManual backgroundTurbine

Valve

Turbine support

and shaft

outlet

 

If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.

BThe letter (P) and dash(es) indicate POSITION switch operation. The letter appearing means the switch is closed; the dash means the switch is open. Use the

RECHARGE Manual background (RECHARGE TONIGHT–RECHARGE NOW) button to manually advance the valve into each cycle and check correct switch operation.

CORRECT SWITCH

 

DISPLAYS

VALVE CYCLE STATUS

— Valve in service, fill, brining, backwash or fast rinse position.

— P

Valve rotating from one position to another

since the SR code number was entered.

2. Press the MODE button and hold in three

seconds until a Service Rating code appears in the display.

For correct water softening system

operation, the model code must be SR22 for model GXSF27E.

To reset the code, press the UP or DOWN button until the correct number shows.

3.Press the MODE button to return to the present time display.

If the code was changed, make ALL the timer settings.

NOTE: If the control is left in a diagnostic display or a flashing display when setting times or hardness, present time automatically returns if a button is not pressed within four minutes.

15

Image 15
Contents Sistema Suavizante de Agua Troubleshooting TipsWater Water Softening SystemPROPER INSTALLATION IMPORTANT SAFETY INFORMATIONREAD ALL INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONSInstallation instructions Important Installation RecommendationsUnpacking and Inspection Keep the softener out of direct sunlight Plan How You Will Install the SoftenerWhere to Install the Softener Tools and Materials Required for InstallationPIPE Typical Installation IllustrationOptional 3-ValveBypass Installation Illustration WATERFig. 3B Step-by-stepinstallation instructions1. INSTALL BYPASS VALVE 4. CONNECT AND RUN THE VALVE DRAIN HOSEFig. 4A 4A. CONNECTING A RIGID VALVE DRAIN TUBE6. INSTALL GROUNDING CLAMP 9.CONNECT TO ELECTRICAL POWERSET RECHARGE STARTING TIME Programming the ControlSET PRESENT TIME OF DAY SET WATER HARDNESS NUMBERSALT EFFICIENCY Optional Control SettingsERROR SIGNALS SYSTEM/ELECTRONIC DIAGNOSTICSSpecifications/Dimensions Sanitizing ProceduresFill About the water softener systemService Automatic Hard Water Bypass During RechargeCleaning the Nozzle and Venturi Assembly Breaking a Salt BridgeDo not overtighten the cap Normal Operation, Control Displays Feature Optional Recharge ControlsFeature Memory Feature/Service Automatic Electronic DiagnosticsVISUAL CHECKS To remove an error code 1. Unplug transformerNO SOFT WATER POSSIBLE DEFECTFor correct water softening system OPENA NEARBY SOFT WATER FAUCETAbout the water softener system Care and cleaning of the water softening system Cleaning Iron Out of the Water Softening SystemChecking the Salt Storage Level and Refilling NO SOFT WATER-MostCommon Problems Before you call for service…system was installed Problemafter installation of not using any saltBrown/yellow water after installationSalty tasting or brown/yellow coloredPage Parts list Page GENERAL ELECTRIC PARTS CATALOG Parts catalog0111 One Year What Is Not CoveredFor The Period Of We Will Replace Staple your receipt hereFor service, call toll free For The Period OfWe Will Replace Page Consejos para la solución Información de seguridadInstrucciones para la Instrucciones para la operaciónADVERTENCIA No use con agua que INFORMACIÓN IMPORTANTE DE SEGURIDADLEA TODAS LAS INSTRUCCIONES ANTES DEL USO PRECAUCIONES DE SEGURIDADRecomendaciones importantes para la instalación Instrucciones de instalaciónADVERTENCIA No use con Desempacado e inspecciónADVERTENCIA Use solamente Planifique la instalación del DescalcificadorDónde instalar el Descalcificador Válvula de bypass Ilustración de instalación normalAGUA PRINCIPALFig. 3C Instrucciones de instalación paso por pasoFig. 3A Fig. 3BDE LA VÁLVULA Reemplace la cubierta superior 6.INSTALE LA ABRAZADERA DE TIERRA8.AGREGUE AGUA Y SAL AL TANQUE DE SALMUERA 9.CONECTE EL SUMINISTRO ELÉCTRICOAJUSTE LA HORA DE INICIO DE RECARGA Programación del controlAJUSTE LA HORA DEL DÍA AJUSTE EL NIVEL DE DUREZA DEL AGUAEFICIENCIA DE LA SAL SEÑALES DE ERRORAjustes opcionales de control DIAGNÓSTICO ELECTRÓNICO/DEL SISTEMAProcedimientos de desinfección Especificaciones/DimensionesLavado Regresivo Sobre el sistema de descalcificación de aguaServicio LlenadoNivel de agua Cómo romper un puente de sal1″-2″ 2,54 cm-5,1cm Sal InstrumentoBoquilla y Venturi Tapa Sello del aro tórico Soporte del filtroFiltro Tapón de flujo Junta Tapón de flujoRECARGO AHORA Operación normal, Pantalla de controlFunción Memoria RECARGUE ESTA NOCHEINSPECCIONES VISUALES VISUALIZADOCORRECTO MUESTRA ESTADO DEL CICLO DE LA VÁLVULA EL INTERRUPTORRECHARGE recargo PRECAUCIÓN Antes de llamar para solicitar servicio… NO HAY AGUA DESCALCIFICADA-Problemasmás comunesresbalosa después de la A veces el aguaestá dura El agua se sientedespués de la instalación Un error de códigoEl agua sabe a sal o tiene aspecto café o amarilloNotas Notas Notas Lista de partes Page CATÁLOGO DE PARTES DE GENERAL ELECTRIC Catálogo de partes0104 Garante General Electric Company. Louisville, KY Por el período deReemplazamos Lo que no está cubiertoGarantías ampliadas Soporte al ConsumidorPágina Web de GE Appliances Solicite una reparaciónGE Appliances Website Schedule ServiceParts and Accessories Consumer Support