English
1a. Power supply cord method
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Check that power supply cord does not touch dishwasher motor or lower part of dishwasher tub. Go to step 5.
Water Connection
HELPFUL TIP:
Compression fittings:
1.Slide nut “I” about 1 inch (2.5 cm) onto copper tubing “J”.
2.Slide ferrule “K” onto the tubing. Do not position ferrule on the end of the tubing.
3.Put the tubing into the elbow “L” as far as it will go.
4. Slide the nut and ferrule forward and start the nut onto the elbow threads “M”. Be careful when handling and positioning the copper tubing as it bends and kinks easily.
5. To prevent vibration during operation, route the water supply line so that it does not touch the dishwasher base, frame or motor.
Make sure the water line stays within the shaded area shown on page 7 when the dishwasher is installed in the cabinet.
With copper tubing “J” pushed into compression fitting as far as it will go, use an adjustable wrench and tighten compression fitting nut “I” to elbow “L” on water inlet valve.
6. Place Paper towel under elbow. Turn on water supply and check for leaks.
21