Installation | Section 2 |
|
|
Installer Instructions
Important
The remainder of these instructions is to be completed by an authorized Multiplex Installer.
Ambient Location Requirement
This equipment is rated for indoor use only. It will not operate in
These equipment instructions are intended to assist qualified personnel in the unpacking, locating and the initial operation of the Multiplex Beverage Equipment Post Mix Refrigeration Unit.
Electrical
GENERAL
Important
This publication must be saved for future reference. Read instructions before attempting installation.
PREPARATION
The Multiplex Beverage Equipment Post Mix Refrigeration Unit is
For future reference or to be used when ordering parts, record the Model Number, Serial Number, Part Numbers of Unit, Condenser (if remote), Towers, etc., and Date of Installation on the inside of this Manual. Leave manual on site in a safe place. Do not discard manual.
SPECIFICATIONS
!Warning
All wiring must conform to local, state and national codes.
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select the wire size of the electrical supply. (Minimum circuit ampacity is not the beverage/ice machine’s running amp load.) The wire size (or gauge) is also dependent upon location, materials used, length of run, etc., so it must be determined by a qualified electrician.
ELECTRICAL REQUIREMENTS
Refer to Ice Machine Model/Serial Plate for voltage/amperage specifications.
Model | Volt/Cycle/Phase | Minimum Circuit Amps | Breaker | Compressor |
|
|
|
|
|
11M | 120/60/1 | 21.5 | 30A | 1/2 hp |
| 230/50/1 | 10.7 | 16A | .97 kW |
|
|
|
|
|
Part Number 020001552 5/11 |