Installation | Section 2 |
|
|
Plumbing/Water Supply
PLUMBING POTABLE WATER
| Required | Drain | Water | |
Model | Water | |||
Connections | Supply | |||
| Pressure | |||
|
|
| ||
|
|
|
| |
11M | 40 – 70 psig | 3/4" ID | 3/8" ID | |
| (2.8 – 4.9 bar) | within 6 ft (2 m) | EVA Line | |
|
|
|
|
A 1" (2.54 cm) ID copper inlet water line equipped with a 3/4" (1.905 cm) FPT sweat adapter with
NOTE: The carbonator in this unit is provided with a dual check valve type
Potable water connections to the equipment must comply with the basic plumbing code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration. Verify local plumbing code requirements.
PLUMBING REQUIREMENTS – GENERAL
Incoming water supply must be provided before installation of the refrigeration unit and must comply with local plumbing requirements.
1.A minimum 1" (2.54 cm) water supply line with a manual
2.Locate the drain hose, bracket, and two screws provided in the installation kit. Attach the drain hose to the water bath overflow tube located on the bottom of the refrigeration unit.
3.Connect the water manifold supply line, located on the bulkhead panel in the motor compartment to the main water supply. The main water supply
Bracket
Bottom
of Unit
Screw
Drain Hose
Drain Hose Connection
4.When a water cooled condenser is installed, a copper supply line (not supplied with unit) must be plumbed to the 3/8" (.965 cm) male flare fitting installed in the water
WATER SUPPLY
1.Use the built in fill valve that is already plumbed into the unit.
2.An appropriate floor drain is required within 6 ft (2 m) of the unit.
3.Potable water connections to the equipment must comply with the basic plumbing code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration. Verify local plumbing code requirements.
Part Number 020001552 5/11 |