Step 4: Installing Anti-Tip Device
For all 30" and 36" ranges, an
WARNING
RANGE TIPPING HAZARD
•All ranges can tip and injury can result. To prevent accidental tipping of the range, attach it to the floor, wall or cabinet by installing the
•A risk of
•If the range is pulled away from the wall for cleaning, service or any other reason, ensure that the
WARNING
•ALL RANGES CAN TIP
•INJURY TO PER- SONS COULD RE- SULT
•INSTALL
•SEE INSTALLATION INSTRUCTIONS
WARNING
ELECTRICAL SHOCK HAZARD
•Use extreme caution when drilling holes into the wall or floor. There may be concealed electrical wires located behind the wall or under the floor.
•Identify the electrical circuits that could be affected by the installation of the
•Failure to follow these instructions may result in electrical shock or other per- sonal injury.
ATTENTION
PROPERTY DAMAGE
•Contact a qualified installer or contractor to determine the proper method for drill- ing holes through the wall or floor material (such as ceramic tile, hardwood, etc.)
•Do not slide the range across an unpro- tected floor.
•Failure to follow these instructions may result in damage to wall or floor cover- ings.
Tools Needed for Installation of Anti-Tip Device:
• Screwdriver, Phillips | • Hammer |
• Drill, electric or hand | • Pencil or other marker |
•Measuring tape or ruler
•1/8" drill bit (wood or metal wall or floor)
•3/16"
•3/16" anchors, drywall or concrete, 4 (not required if mounting bracket is being attached to solid wood or metal)
10