Step 9: Burner Test and Adjustment
Flame Adjustment (if necessary):
•Loosen shutter screw(s) and turn shutter to new position.
•Adjust the shutter to
•Retighten the shutter screw(s).
•After adjustment, reinstall the burner and per- form flame evaluation. The air shutter must fit over the orifice hood for proper operation of the burner.
•Repeat procedure as needed until flame char- acteristics are acceptable. (See Figure 14).
FIG. 15 Air Shutter Adjustment (if necessary)
| Air | Screw |
More Open: |
| |
Shutter |
| |
Less Yellow Flame |
|
|
More Closed: |
|
|
Less Blue Flame |
|
|
More Carryover |
|
|
Less Lifting or Blowing |
|
|
WARNING
Burner adjustments must be performed by a qualified technician. Improper adjustments may cause harmful
Allow burners to cool before attempting to remove them!
Call Thermador® if:
1.Any of the burners do not light.
2.Any of the burners continue to burn yellow.
19