Thermador PD30 Flame Adjustment if necessary, Air Shutter Adjustment if necessary

Page 22

Step 9: Burner Test and Adjustment

Flame Adjustment (if necessary):

Tube-style gas burners used in Thermador© appli- ances have air shutter systems which are similar to the illustration in Figure 15, and can be adjusted using the following method (unless adjustment is not recommended). It is necessary to remove the burner from the appliance in order to perform air- shutter adjustments.

Loosen shutter screw(s) and turn shutter to new position.

Adjust the shutter to more-closed position if the flame is lifting or blowing, or is not carrying over. Adjust the shutter to more-open position if the flame is too yellow. (See Figure 15.)

Retighten the shutter screw(s).

After adjustment, reinstall the burner and per- form flame evaluation. The air shutter must fit over the orifice hood for proper operation of the burner.

Repeat procedure as needed until flame char- acteristics are acceptable. (See Figure 14).

FIG. 15 Air Shutter Adjustment (if necessary)

 

Air

Screw

More Open:

 

Shutter

 

Less Yellow Flame

 

 

More Closed:

 

 

Less Blue Flame

 

 

More Carryover

 

 

Less Lifting or Blowing

 

 

WARNING

Burner adjustments must be performed by a qualified technician. Improper adjustments may cause harmful by-products or void the appliance's warranty.

Allow burners to cool before attempting to remove them!

Call Thermador® if:

1.Any of the burners do not light.

2.Any of the burners continue to burn yellow.

19

Image 22
Contents Installation Instructions Please Read Entire Instructions Before Proceeding For Massachusetts InstallationsWhat to do if YOU Smell GAS Contents GAS Type Verification Important Installation InformationGas Supply Select Hood and Blower Models Hood PlacementVentilation Requirements Consider Make-Up AirCabinet Preparation Cabinet Clearances Side View GAS and Electric Supply Zones NPTElectrical Supply Wall ConnectionOn Page 5. Do not remove Unpacking, Moving and Placing The RangeGrill or griddle assemblies Grill / Griddle Tilt Adjustment Not on all models Range Tipping Hazard Installing Anti-Tip DeviceProperty Damage 36 Inch Ranges Figures 7A and 7B Important Installation InformationMounting ANTI-TIP Bracket Natural Gas Requirements Gas Requirements and HookupHook UP Propane Gas RequirementsChart B Electrical Supply Circuit Requirements Electrical Requirements, Connection & GroundingTo the Power Supply Power Supply with aWire is Impractical Conductor CordWire Lead Connection Wire ConnectionBackguard Installation Chart C Backguard KIT Model NumbersDoor Removal and Installation USE Caution When Removing the DOOR. the Door is Very HeavyYellow Flames Burner Test and AdjustmentWhen Flame is Properly Adjusted Yellow Tips on Outer ConesFlame Adjustment if necessary Air Shutter Adjustment if necessaryGAS Supply To Clean and Protect Exterior SurfacesFinal Check List ElectricalPage Avertissement Consultez LES Instructions D’INSTALLATIONVeuillez lire toutes les instructions Avant de poursuivre SI Vous Sentez UNE Odeur DE GAZTable des matières Le branchement et la mise à la terreVérification DU Type DE GAZ Information Importante concernant l’installationMise EN Garde Alimentation pour le gazChoix du modèle de hotte et de ventilateur Emplacement de la hotteChapitre 1 Exigences de ventilation Apport d’airChapitre 2 Préparation de l’emplacement Dégagement des armoires Vue latérale Conversion des mesuresRaccordée qu’au type Gaz De toutes les cuisinières mixtesLa cuisinière Ne doit Être Pour lequel elle est certifiée. SiAlimentation Électrique Raccordement AU MUR5. N’ôtez pas le gril ni la Plaque de cuissonAjustement de l’inclinaison de la plaque de cuisson Avertissement Risque D’ÉLECTROCUTION Chapitre 4 Installation du dispositif antibasculeAvertissement Danger DE Renversement Risque DE DommagesInformations Importantes À Propos DE L’INSTALLATION Montage de la patte antibasculeRaccordement Exigences pour le gaz naturelTableau B Exigences des circuits d’alimentation électrique 240/208 VCA Amps 60 Hz Monophasé’ALIMENTATION À Quatre SI LES RéglementationsET QUE LA Conversion DE Peut Être Connecté ÀConnexion à 3 fils Connexion à 4 filsChapitre 7 Installation de la plaque de protection Tableau C Références Pour LES Plaques DE ProtectionChapitre 8 Enlever et installation de la porte Pour enlever la porte du fourVérifier la flamme. Réglage bas. Tourner le bouton Chapitre 9 Test et réglage de brûlerLorsque LA Flamme EST Adéquatement Réglée Réglage de flamme au besoin Alimentation EN GAZ Liste de vérification pour l’installateurListe Finale DE Vérification FonctionnementRemarques