Thermador PD30 Please Read Entire Instructions Before Proceeding, For Massachusetts Installations

Page 2

Please Read Entire Instructions

Before Proceeding

IMPORTANT: Save these instructions for the Local Electric and Gas Inspector’s use. INSTALLER: Please leave these Installation Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

WARNING

Disconnect power before installing. Before turning powerON, be sure that all controls are in the OFF position.

IMPORTANT

Local codes vary. Installation, gas connections and grounding must comply with all applicable codes.

For Massachusetts Installations:

1.Installation must be performed by a qualified or licensed contractor, plumber or gas fitter qualified or licensed by the state, province or region where this appliance is being installed.

2.Shut-off valve must be a “T” handle gas cock.

3.Flexible gas connector must not be longer than 36 inches.

WARNING:

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING

ALL RANGES CAN TIP

INJURY TO PERSONS COULD RESULT

INSTALL ANTI-TIP DEVICE

SEE INSTALLATION INSTRUCTIONS

TO REDUCE THE RISK OF TIPPING OF THE APPLIANCE, IT MUST BE SECURED BY A PROPERLY INSTALLED ANTI-TIP DEVICE. VERIFY THAT THE ANTI-TIP DEVICE IS ENGAGED PER INSTALLATION INSTRUCTIONS. (NOTE: ANTI-TIP DEVICE IS REQUIRED ON ALL 30" AND 36" RANGES).

Note: This Range is NOT designed for installation in manufactured (mobile) homes or for installation in Recreational Park Trailers.

DO NOT install this range outdoors.

Image 2
Contents Installation Instructions What to do if YOU Smell GAS For Massachusetts InstallationsPlease Read Entire Instructions Before Proceeding Contents Gas Supply Important Installation InformationGAS Type Verification Select Hood and Blower Models Hood PlacementVentilation Requirements Consider Make-Up AirCabinet Preparation Cabinet Clearances Side View GAS and Electric Supply Zones NPTElectrical Supply Wall ConnectionGrill or griddle assemblies Unpacking, Moving and Placing The RangeOn Page 5. Do not remove Grill / Griddle Tilt Adjustment Not on all models Property Damage Installing Anti-Tip DeviceRange Tipping Hazard Mounting ANTI-TIP Bracket Important Installation Information36 Inch Ranges Figures 7A and 7B Natural Gas Requirements Gas Requirements and HookupHook UP Propane Gas RequirementsChart B Electrical Supply Circuit Requirements Electrical Requirements, Connection & GroundingTo the Power Supply Power Supply with aWire is Impractical Conductor CordWire Lead Connection Wire ConnectionBackguard Installation Chart C Backguard KIT Model NumbersDoor Removal and Installation USE Caution When Removing the DOOR. the Door is Very HeavyYellow Flames Burner Test and AdjustmentWhen Flame is Properly Adjusted Yellow Tips on Outer ConesFlame Adjustment if necessary Air Shutter Adjustment if necessaryGAS Supply To Clean and Protect Exterior SurfacesFinal Check List ElectricalPage Avertissement Consultez LES Instructions D’INSTALLATIONVeuillez lire toutes les instructions Avant de poursuivre SI Vous Sentez UNE Odeur DE GAZTable des matières Le branchement et la mise à la terreVérification DU Type DE GAZ Information Importante concernant l’installationMise EN Garde Alimentation pour le gazChoix du modèle de hotte et de ventilateur Emplacement de la hotteChapitre 1 Exigences de ventilation Apport d’airChapitre 2 Préparation de l’emplacement Dégagement des armoires Vue latérale Conversion des mesuresRaccordée qu’au type Gaz De toutes les cuisinières mixtesLa cuisinière Ne doit Être Pour lequel elle est certifiée. SiAlimentation Électrique Raccordement AU MUR5. N’ôtez pas le gril ni la Plaque de cuissonAjustement de l’inclinaison de la plaque de cuisson Avertissement Risque D’ÉLECTROCUTION Chapitre 4 Installation du dispositif antibasculeAvertissement Danger DE Renversement Risque DE DommagesInformations Importantes À Propos DE L’INSTALLATION Montage de la patte antibasculeRaccordement Exigences pour le gaz naturelTableau B Exigences des circuits d’alimentation électrique 240/208 VCA Amps 60 Hz Monophasé’ALIMENTATION À Quatre SI LES RéglementationsET QUE LA Conversion DE Peut Être Connecté ÀConnexion à 3 fils Connexion à 4 filsChapitre 7 Installation de la plaque de protection Tableau C Références Pour LES Plaques DE ProtectionChapitre 8 Enlever et installation de la porte Pour enlever la porte du fourLorsque LA Flamme EST Adéquatement Réglée Chapitre 9 Test et réglage de brûlerVérifier la flamme. Réglage bas. Tourner le bouton Réglage de flamme au besoin Alimentation EN GAZ Liste de vérification pour l’installateurListe Finale DE Vérification FonctionnementRemarques