4.Remove 2 screws from the bake burner.

5.Slide the front of the bake burner to the side to remove tab from front of oven. Lift the back of the bake burner off the oven orifice, and set the bake burner aside. Do not disconnect the wire.

A

B

10.Position the front of the oven bottom panel toward the front frame, and then lower the rear of the oven bottom panel into the oven.

11.Reattach the oven bottom panel with 2 screws and 2 washers.

To Convert Oven Broil Burner (LP Gas to Natural Gas)

1.Remove 1 screw from the broil burner.

2.Remove the flame spreader.

3.Remove the broil burner from the broil burner orifice hood.

NOTE: The broil burner will hang in the back of the oven while you are changing the orifice hood.

A. Bake burner

B. Screws

A

A. Oven orifice

6.Apply masking tape to the end of a ³⁄₈" (1 cm) nut driver to help hold the gas orifice spud in the nut driver while changing it. Press nut driver down onto the gas orifice spud and remove by turning the LP gas bake burner orifice spud counterclockwise to remove. The spud will be stamped with a “56.”

7.Replace the “56” spud with a “47” spud. Install the Natural gas bake burner orifice spud, turning it clockwise until snug.

IMPORTANT: Do not overtighten.

A

A. Orifice spud

8.Position the back of the bake burner over the oven orifice, and then align the holes for the screws.

9.Reattach the bake burner with 2 screws.

A

C

B

D

A. Broil burner

B. Flame spreader

C.Screws

D.Orifice hood

4.Apply masking tape to the end of a ³⁄₈" (1 cm) nut driver to help hold the gas orifice spud in the nut driver while changing it. Press nut driver down onto the gas orifice spud and remove by turning the LP gas broil burner orifice hood counterclockwise to remove. The hood will be stamped with a “100.”

5.Replace the “100” hood with a “155” hood. Install the Natural gas broiler burner orifice hood, turning it clockwise until snug.

IMPORTANT: Do not overtighten.

A

A. Orifice hood

6.Place the broil burner on the broil burner orifice hood. Insert the broil burner ceramic igniter in the hole in the rear of the oven.

7.Replace the flame spreader with all 4 tabs facing up and the notches toward the rear of the oven.

8.Position the broil burner against the top of the oven and attach it with 1 screw.

21

Image 21
Contents GAZ Encastrables DE 30 76,2 CM Instructions Pour L’INSTALLATION DES CuisinièresYour safety and the safety of others are very important Range SafetyAnti-Tip Bracket Range Foot Installation Requirements Tools and PartsLocation Requirements Product Dimensions Mobile Home Additional Installation RequirementsMobile Home Installations Require Model KSGB900Cabinet Dimensions Slide-In Cutout Freestanding Cutout¹¹⁄₁₆ 9.4 cm plus measurement of N L 30.5 cm Gas Supply Requirements Electrical RequirementsType of Gas Gas Supply LineGas Supply Pressure Testing Gas Pressure RegulatorBurner Input Requirements Install Anti-Tip Bracket Installation InstructionsUnpack Range 12½ 31.8 cm B. Bracket V-notchFloor Mounting Adjust Leveling LegsWall Mounting Rear position Front positionMake Gas Connection Level RangeTypical Flexible Connection Complete ConnectionFor Models MGS8880D, WEG730H0D, and WEG760H0D For Models KSGG700E and KSGB900EFor Model JGS1450D Electronic Ignition System Verify Anti-Tip Bracket Is Installed EngagedOven Door Remove/Replace DrawerCheck Operation of Oven Broil Burner To RemoveIf You Need Assistance or Service Complete InstallationIf Range Does Not Operate, Check the Following Hinge notchLP Gas Conversion GAS ConversionsTo Convert Gas Pressure Regulator Natural Gas to LP Gas Gas pressure regulatorTo Convert Oven Bake Burner Natural Gas to LP Gas To Convert Surface Burners Natural Gas to LP GasTo Convert Oven Broil Burner Natural Gas to LP Gas Bake burner Screws Oven orificeBroil burner Flame spreader Screws Orifice hood Complete Installation Natural Gas to LP Gas Natural Gas ConversionTo Convert Gas Pressure Regulator LP Gas to Natural Gas To Convert Oven Bake Burner LP Gas to Natural Gas To Convert Surface Burners LP Gas to Natural GasStamped number Igniter electrode Orifice spud Screws Orifice spud holderTo Convert Oven Broil Burner LP Gas to Natural Gas Adjust Flame Height Complete Installation LP Gas to Natural GasAdjust Surface Burner Flame Adjust Oven Broil Burner Flame If Needed Adjust Oven Bake Burner Flame If NeededIf Flame Needs to be Adjusted Locking screw Air shutterVotre sécurité et celle des autres est très importante Sécurité DE LA CuisinièrePied de La cuisinière Exigences D’INSTALLATION Exigences demplacementOutillage et pièces Dimensions du produit Modèle KSGB90029⁷⁄₈ 75,9 cm ¹¹⁄₁₆ 9,4 cm plus la mesure de N L 30,5 cm Dimensions du placardSpécifications de l’alimentation en gaz Spécifications électriquesType de gaz Gaz naturelDétendeur Canalisation dalimentation en gazDébit thermique des brûleurs Tests de pressurisation de la canalisation de gazInstallation de la bride antibasculement Instructions D’INSTALLATIONDéballage de la cuisinière 12½ 31,8 cm Encoche en V de la brideMontage au plancher Réglage des pieds de nivellementMontage mural Position arrière Position avantRaccordement au gaz Réglage de l’aplomb de la cuisinièreRaccordement typique par raccord flexible Achever le raccordementPour les modèles MGS8880D, WEG730H0D et WEG760H0D Pour les modèles KSGG700E et KSGB900EPour le modèle JGS1450D Avertissement Système d’allumage électronique Porte du four Dépose et réinstallation du tiroirAchever l’installation Pour obtenir de l’assistance ou une visite de serviceSi la cuisinière ne fonctionne pas, contrôler ce qui suit Conversion pour l’alimentation au propane Conversions Pour Changement DE GAZDétendeur Électrode d’allumage Gicleur Support du gicleur VisRainure pour gaz propane Conversion du brûleur de cuisson au four de gaz naturel Gaz propaneBrûleur de cuisson au four Vis Orifice du four Vis Partie inférieure du fourAchever l’installation de gaz naturel à propane Conversion pour l’alimentation au gaz naturel Capuchon en plastiqueRondelle Capuchon du détendeur Chiffre gravé Brûleur de cuisson au four Vis Réglage de la taille des flammes Achever l’installation gaz propane à gaz naturelRéglage de la flamme des brûleurs de surface Réglage des brûleurs standardsVis de blocage Virole de réglage de l’admission d’air ’il est nécessaire de régler la taille des flammesW10665256D