1Safety Guidelines

!Danger

:Suffocation from exhaust fume

￿Exhaust fume from the engine contains many elements harmful to human. Do not operate this equipment in poorly ventilated area, such as inside a room or in a tunnel

!Danger

:Electrical Shock

￿Do not touch the output terminals during operation.

￿Be sure to place covers over the output terminals and fasten with fasteners.

￿Do not insert metal objects (such as pin or wire) into plug-in receptacles.

￿Do not touch wiring or any electronic parts inside equipment during operation.

￿Ground the every earth grounding terminal to the earth as set out in the manual.

If even one of all is unconnected by mistake or accident, it will be much more dangerous for human body than the NO RELAY case, because leaking current inevitably goes through the body.

￿Even though all the earth terminals of the loads have been grounded to the earth,

the earth grounding terminal and the outer bonnet (canopy) grounding terminal should be grounded to the earth.

￿There is always a danger of being electrocuted by short-circuit. Be sure to test generator’s insulation resistance periodically.

￿Before connecting or disconnecting a load cable to/from output terminals, always turn a circuit breaker to OFF position, stop the engine, and remove the engine key. A person performing the maintenance should always keep the key.

￿Before performing any equipment check or maintenance, stop the engine, and remove the engine key. A person performing the maintenance should always keep the key.

!Danger

:Injuries

￿ Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.

! Caution

:Suffocation from exhaust fume

￿Do not point the exhaust fume toward pedestrians or building.

- 3 -

Image 3
Contents DG150MI DG250MI Table of ContentsIntroduction Injuries Safety GuidelinesSuffocation from exhaust fume Electrical ShockInjuries to eyes and skin FireBurns Location of Warning labels Control Panel Unit Name of Generator SpecificationsSpecification Matrix Alternator EngineParts Ambient ConditionExternal view Name Control panelWater Temperature Monitoring Lamp for temperature High EquipmentMonitor Display Engine Oil Monitoring Lamp for oil pressure low Battery Charge Monitoring Lamp charge lamp Hour Meter GaugesFluid Level Monitoring Lamp DG250MI only Tachometer DG250MI onlyLamp Water Temperature Gauge DG250MI onlyOil Pressure Gauge DG250MI only Generator GaugesSwitch Throttle Handle Fuel Line Changeover Valve 3-way valveVoltage Regulator and Throttle Handle Voltage RegulatorTransportation Transport and InstallationUsing fuel from built-in fuel tank Using fuel from external fuel tankTransportation InstallationConnection Selecting CableElectrical damages Connecting Cable Load Connection Terminal Plate 3-Phase / 1-phase 2 1-Phase Output Terminals & Receptacles 2.1 2002.2 400 Grounding Work Earth Leakage Relay and GroundingEarth leakage breaker relay has activated Operation CheckFire Burns Initialization and pre-checkChecking Engine Oil Electrical Shock InjuriesViscosity and temperature Checking Coolant / WaterEngine Oil Capacity Checking Coolant reservoir tank / Adding coolant Checking Radiator / Adding waterCondition Checking Fan BeltCoolant Capacity TensionChecking Fuel Checking Battery Replacing the batteryChecking Fuel, Engine Oil, and Water leakage Initializing / preparation OperationPost startup check During OperationAdjustment During operation Stopping the Generator Protection⑥ FeaturesConnecting to External Fuel Tank Protection Feature ListOverload Turn the lever for 3-way valve to B position MaintenanceGenerator side Oil Change Oil Filter ChangeModel Isuzu Part No Cleaning / Changing Fuel Filter Cleaning / Changing Air Filter ElementDraining Water from Fuel Tank Changing Coolant / WaterModel Long-term Storage Storage ProceduresStacking TroubleshootingSymptoms Possible Cause Corrective Actions Generator Wiring Diagram Page Page Page Engine Wiring Diagram