5Equipment

5.1Monitor Display

[DG250MI]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WATER TEMP

 

OIL PRESS

 

 

+CHARGE-

AIR FILTER

BATTERY+ LOW LEVEL-

[DG150MI]

FUEL LEVEL

DG250MI is equipped with monitoring function for water/coolant temperature, oil pressure, battery charge, air filter flow, battery fluid level, and fuel level. DG150MI is equipped with monitoring function for water/coolant temperature, oil pressure and battery charge.

When the equipment is started under normal condition, Oil Pressure and Battery Charge lamps will flash when the Starter Switch is turned from STOP to OPERATING, and all lamps will go off, immediately after the engine is started.

When the abnormality is detected either in water temperature or in oil pressure, the corresponding monitor lamp will flash, and the automatic shutoff shall be engaged.

When the automatic shutoff is engaged, turn the starter switch to STOP position, then restart the engine. When the automatic shutoff is engaged next time, check all parts of the corresponding alarm.

5.1.1 Water Temperature Monitoring Lamp (for temperature High)

!Danger

:Injuries

￿Close all doors and place locks during operating this equipment, to avoid injuries by unintentionally touching cooling fan and fan belt.

!Caution

:Burns

￿Do not open the radiator cap while operating this equipment or immediately after stopping the equipment, to avoid sustaining burns from hot vapor.

￿Do not touch the engine and muffler during operation and immediately after stopping the equipment, for the temperature can reach extremely high.

- 9 -

Image 9
Contents DG150MI DG250MI Table of ContentsIntroduction Suffocation from exhaust fume Safety GuidelinesElectrical Shock InjuriesInjuries to eyes and skin FireBurns Location of Warning labels Specification Matrix SpecificationsAlternator Engine Control Panel Unit Name of GeneratorParts Ambient ConditionExternal view Name Control panelWater Temperature Monitoring Lamp for temperature High EquipmentMonitor Display Engine Oil Monitoring Lamp for oil pressure low Battery Charge Monitoring Lamp charge lamp Fluid Level Monitoring Lamp DG250MI only GaugesTachometer DG250MI only Hour MeterOil Pressure Gauge DG250MI only Water Temperature Gauge DG250MI onlyGenerator Gauges LampSwitch Voltage Regulator and Throttle Handle Fuel Line Changeover Valve 3-way valveVoltage Regulator Throttle HandleUsing fuel from built-in fuel tank Transport and InstallationUsing fuel from external fuel tank TransportationTransportation InstallationConnection Selecting CableElectrical damages Connecting Cable Load Connection Terminal Plate 3-Phase / 1-phase 2 1-Phase Output Terminals & Receptacles 2.1 2002.2 400 Grounding Work Earth Leakage Relay and GroundingEarth leakage breaker relay has activated Operation CheckChecking Engine Oil Initialization and pre-checkElectrical Shock Injuries Fire BurnsViscosity and temperature Checking Coolant / WaterEngine Oil Capacity Checking Coolant reservoir tank / Adding coolant Checking Radiator / Adding waterCoolant Capacity Checking Fan BeltTension ConditionChecking Fuel Checking Battery Replacing the batteryChecking Fuel, Engine Oil, and Water leakage Initializing / preparation OperationPost startup check During OperationAdjustment During operation Stopping the Generator Protection⑥ FeaturesConnecting to External Fuel Tank Protection Feature ListOverload Turn the lever for 3-way valve to B position MaintenanceGenerator side Oil Change Oil Filter ChangeModel Isuzu Part No Cleaning / Changing Fuel Filter Cleaning / Changing Air Filter ElementDraining Water from Fuel Tank Changing Coolant / WaterModel Long-term Storage Storage ProceduresStacking TroubleshootingSymptoms Possible Cause Corrective Actions Generator Wiring Diagram Page Page Page Engine Wiring Diagram