11.2Stacking

!Danger

: Injuries

If you have to stack two generators in warehouse, always proceed with the following steps.

￿Ensure that there is no dent on bonnet, loosing bolt or no bolt in the generators.

￿Always place the generators on a flat and stable surface, to keep the equipment from sliding, And to be endurable for the total weight.

￿When lifting the equipment, always use a lift hook.

￿Always place ties (sleepers) on the marked points in the lower generator firstly and then stack the upper generator on it. All the ties should be the same size (dimension) and longer than the width of the lower generator.

￿Do not stack more than 2 units. The lower generator should be bigger than the upper generator in size and weight.

￿Do not operate the stacking/stacked generators.

12Troubleshooting

!Danger

:Electrical Shock

￿Do not operate the equipment, if the equipment or you are wet.

Before performing any equipment check or maintenance, stop the engine.

-40 -

Image 40
Contents Table of Contents DG150MI DG250MIIntroduction Safety Guidelines Suffocation from exhaust fumeElectrical Shock InjuriesFire Injuries to eyes and skinBurns Location of Warning labels Specifications Specification MatrixAlternator Engine Control Panel Unit Name of GeneratorAmbient Condition PartsExternal view Control panel NameEquipment Water Temperature Monitoring Lamp for temperature HighMonitor Display Engine Oil Monitoring Lamp for oil pressure low Battery Charge Monitoring Lamp charge lamp Gauges Fluid Level Monitoring Lamp DG250MI onlyTachometer DG250MI only Hour MeterWater Temperature Gauge DG250MI only Oil Pressure Gauge DG250MI onlyGenerator Gauges LampSwitch Fuel Line Changeover Valve 3-way valve Voltage Regulator and Throttle HandleVoltage Regulator Throttle HandleTransport and Installation Using fuel from built-in fuel tankUsing fuel from external fuel tank TransportationInstallation TransportationSelecting Cable ConnectionElectrical damages Connecting Cable Load Connection Terminal Plate 3-Phase / 1-phase 2.1 200 2 1-Phase Output Terminals & Receptacles2.2 400 Earth Leakage Relay and Grounding Grounding WorkOperation Check Earth leakage breaker relay has activatedInitialization and pre-check Checking Engine OilElectrical Shock Injuries Fire BurnsChecking Coolant / Water Viscosity and temperatureEngine Oil Capacity Checking Radiator / Adding water Checking Coolant reservoir tank / Adding coolantChecking Fan Belt Coolant CapacityTension ConditionChecking Fuel Replacing the battery Checking BatteryChecking Fuel, Engine Oil, and Water leakage Operation Initializing / preparationDuring Operation Post startup checkStopping the Generator Protection⑥ Features Adjustment During operationProtection Feature List Connecting to External Fuel TankOverload Maintenance Turn the lever for 3-way valve to B positionGenerator side Oil Filter Change Oil ChangeModel Isuzu Part No Cleaning / Changing Air Filter Element Cleaning / Changing Fuel FilterChanging Coolant / Water Draining Water from Fuel TankModel Storage Procedures Long-term StorageTroubleshooting StackingSymptoms Possible Cause Corrective Actions Generator Wiring Diagram Page Page Page Engine Wiring Diagram