Push the reset button or stop the engine.

Restore (Push-down) the 3-Phase circuit breaker (lever) and the 1-Phase circuit breaker (lever) to OFF

position.

By the above procedure, you can reset the breakers to ON positions.

8 Initialization and pre-check

!

Danger

 

:Electrical Shock Injuries

Before performing any equipment check or maintenance, stop the engine, and remove the engine key. A person performing the maintenance should always keep the key.

! Caution

:Fire Burns

When checking engine, always stop the engine, and keep away from fire.

Wait until the engine cools down, before performing any checks.

!Caution

:Fire

Always wipe any drip of fuel or oil. Do not use this equipment when a leak is found.

Repair the equipment before use.

8.1 Checking Engine Oil

Please refer to the user’s manual for Engine separately

When checking for engine oil, be sure to keep the equipment leveled, and insert the oil gauge all the way. Prior to starting the equipment, make sure to fill the engine oil to the MAX line through the oil filler.

<Caution>

￿ If the equipment is not leveled, you cannot obtain accurate oil level.

￿ Do not overfill the engine oil. The excessive amount of engine oil may damage the engine.

8.1.1 Selecting proper engine oil Use the API class CD grade or higher.

8.1.2 Use the engine oil for Diesel engine with proper viscosity, based on the temperature

(refer to the chart below).

- 24 -

Image 24
Contents Table of Contents DG150MI DG250MIIntroduction Safety Guidelines Suffocation from exhaust fumeElectrical Shock InjuriesInjuries to eyes and skin FireBurns Location of Warning labels Specifications Specification MatrixAlternator Engine Control Panel Unit Name of GeneratorParts Ambient ConditionExternal view Control panel NameWater Temperature Monitoring Lamp for temperature High EquipmentMonitor Display Engine Oil Monitoring Lamp for oil pressure low Battery Charge Monitoring Lamp charge lamp Gauges Fluid Level Monitoring Lamp DG250MI onlyTachometer DG250MI only Hour MeterWater Temperature Gauge DG250MI only Oil Pressure Gauge DG250MI onlyGenerator Gauges LampSwitch Fuel Line Changeover Valve 3-way valve Voltage Regulator and Throttle HandleVoltage Regulator Throttle HandleTransport and Installation Using fuel from built-in fuel tankUsing fuel from external fuel tank TransportationInstallation TransportationConnection Selecting CableElectrical damages Connecting Cable Load Connection Terminal Plate 3-Phase / 1-phase 2 1-Phase Output Terminals & Receptacles 2.1 2002.2 400 Earth Leakage Relay and Grounding Grounding WorkOperation Check Earth leakage breaker relay has activatedInitialization and pre-check Checking Engine OilElectrical Shock Injuries Fire BurnsViscosity and temperature Checking Coolant / WaterEngine Oil Capacity Checking Radiator / Adding water Checking Coolant reservoir tank / Adding coolantChecking Fan Belt Coolant CapacityTension ConditionChecking Fuel Checking Battery Replacing the batteryChecking Fuel, Engine Oil, and Water leakage Operation Initializing / preparationDuring Operation Post startup checkStopping the Generator Protection⑥ Features Adjustment During operationConnecting to External Fuel Tank Protection Feature ListOverload Maintenance Turn the lever for 3-way valve to B positionGenerator side Oil Change Oil Filter ChangeModel Isuzu Part No Cleaning / Changing Air Filter Element Cleaning / Changing Fuel FilterDraining Water from Fuel Tank Changing Coolant / WaterModel Storage Procedures Long-term StorageTroubleshooting StackingSymptoms Possible Cause Corrective Actions Generator Wiring Diagram Page Page Page Engine Wiring Diagram