Shindaiwa DG250MI, DG150MI specifications Symptoms Possible Cause Corrective Actions

Page 41

! Caution

:Injuries

￿ When performing equipment check and maintenance, always stop the engine.

! Caution

:Fire ￿ Burns

￿Battery may emit some combustible gas, so keep it away from fire and sparks.

￿Temperature around muffler and exhaust can get extremely high. Keep any inflammable items (such as fuel, gas, paint, etc.) away from the equipment.

￿When checking engine oil or changing oil, always stop the engine, and wait until the engine cools down. If you open either the oil gauge or the oil filler cap during operation, hot oil may cause some injury.

Follow the guideline below, when performing any troubleshooting. If you cannot resolve the problems by this troubleshooting guide, contact the authorized distributor or our engineering section to request the repair.

Symptoms

Possible Cause

Corrective Actions

Starter motor does not start

1.

Weak battery

1.

Recharge battery

 

2.

Dead battery

2.

Replace battery

Engine does not start

1.

Fuel lever to CLOSE

1.

Fuel lever to OPEN

 

2.

Insufficient fuel

1.

Replenish fuel

 

3.

Water contaminants in

2.

Drain water or clean fuel

 

 

fuel

 

tank, fuel filter, and water

 

 

 

 

sedimenter

Engine starts, but stalls

1.

Insufficient oil

1.

Replenish oil

immediately

2.

Insufficient coolant/water

2.

Replenish water

 

3.

Air in the fuel system

3.

Vacuum out air

No AC output

1.

Circuit breaker is OFF

1.

Turn circuit breaker to ON

Weak AC output

1.

Wrong frequency

1.

Adjust the frequency to

 

2.

Connected equipment’s

 

match the connected

 

 

amperage exceeds the

 

equipment

 

 

rated value(Overload)

2.

Use equipment within the

 

3.

Multiple equipment

 

rated amperage

 

 

being connected

3.

Connect load to

 

 

simultaneously

 

generator one by one

 

4.

Low SPEED

4.

Increase SPEED

Voltage sharply drops when

1.

Uneven load balance

1.

Change connection

connected machines start up

 

connection

 

 

Cannot turn circuit breaker to

1.

Circuit breaker is not

1.

Push circuit breaker to

ON position

 

completely turned to

 

OFF position

 

 

OFF position

2.

Check load side

 

2.

Short-circuit on load side

3.

Repair the leakage point

 

3.

Earth leakage relay

 

 

 

 

activated

 

 

Black or white smoke is coming

1.

Overloading

1.

Reduce the load

out of exhaust pipe

 

 

 

 

successively.

 

 

 

 

 

 

 

 

 

 

 

- 41 -

 

 

Image 41
Contents DG150MI DG250MI Table of ContentsIntroduction Suffocation from exhaust fume Safety GuidelinesElectrical Shock InjuriesBurns Injuries to eyes and skinFire Location of Warning labels Specification Matrix SpecificationsAlternator Engine Control Panel Unit Name of GeneratorExternal view PartsAmbient Condition Name Control panelMonitor Display Water Temperature Monitoring Lamp for temperature HighEquipment Engine Oil Monitoring Lamp for oil pressure low Battery Charge Monitoring Lamp charge lamp Fluid Level Monitoring Lamp DG250MI only GaugesTachometer DG250MI only Hour MeterOil Pressure Gauge DG250MI only Water Temperature Gauge DG250MI onlyGenerator Gauges LampSwitch Voltage Regulator and Throttle Handle Fuel Line Changeover Valve 3-way valveVoltage Regulator Throttle HandleUsing fuel from built-in fuel tank Transport and InstallationUsing fuel from external fuel tank TransportationTransportation InstallationElectrical damages ConnectionSelecting Cable Connecting Cable Load Connection Terminal Plate 3-Phase / 1-phase 2.2 400 2 1-Phase Output Terminals & Receptacles2.1 200 Grounding Work Earth Leakage Relay and GroundingEarth leakage breaker relay has activated Operation CheckChecking Engine Oil Initialization and pre-checkElectrical Shock Injuries Fire BurnsEngine Oil Capacity Viscosity and temperatureChecking Coolant / Water Checking Coolant reservoir tank / Adding coolant Checking Radiator / Adding waterCoolant Capacity Checking Fan BeltTension ConditionChecking Fuel Checking Fuel, Engine Oil, and Water leakage Checking BatteryReplacing the battery Initializing / preparation OperationPost startup check During OperationAdjustment During operation Stopping the Generator Protection⑥ FeaturesOverload Connecting to External Fuel TankProtection Feature List Turn the lever for 3-way valve to B position MaintenanceGenerator side Model Isuzu Part No Oil ChangeOil Filter Change Cleaning / Changing Fuel Filter Cleaning / Changing Air Filter ElementModel Draining Water from Fuel TankChanging Coolant / Water Long-term Storage Storage ProceduresStacking TroubleshootingSymptoms Possible Cause Corrective Actions Generator Wiring Diagram Page Page Page Engine Wiring Diagram