Briggs & Stratton 2900 PSI manual Long Term Storage

Page 22

Long Term Storage

If you do not plan to use the pressure washer for more than 30 days, you must prepare the engine and pump for long term storage.

Protect Fuel System

Fuel Additive:

Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use Briggs

&Stratton FRESH START™ fuel stabilizer, available as a liquid additive or a drip concentrate cartridge.

There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to

24 months.

If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.

Change Oil

While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil in Engine Maintenance.

Oil Cylinder Bore

Remove spark plug and pour about 1/2 ounce (15 ml) of clean engine oil into the cylinder.

Install spark plug and pull starter handle slowly to distribute oil.

Protecting the Pump

To protect the pump from damage caused by mineral deposits or freezing, use PumpSaver, Model 6039, to treat pump. This prevents freeze damage and lubricates pistons and seals.

NOTICE

You must protect your unit from freezing temperatures.

Failure to do so will permanently damage your pump and render your unit inoperable.

Freeze damage is not covered under warranty.

NOTE: PumpSaver is available as an optional accessory. It is not included with the pressure washer. Contact the nearest authorized service center to purchase PumpSaver.

To use PumpSaver, make sure the pressure washer is turned off and disconnected from supply water. Read and follow all instructions and warnings given on the PumpSaver container.

Other Storage Tips

1.DO NOT store fuel from one season to another unless it has been treated as described in Protect Fuel System.

2.Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it’s used with this unit.

3.Cover unit with a suitable protective cover that does not retain moisture.

WARNING

Storage covers can be flammable.

DO NOT place a storage cover over a hot pressure washer.

Let equipment cool for a sufficient time before placing the cover on the equipment.

4.Store unit in a clean and dry area.

22

BRIGGSandSTRATTON.COM

Image 22
Contents Operator’s Manual Engine Where to Find UsPressure Washer Date PurchasedTable of Contents Hazard Symbols and Meanings Operator SafetySafety Rules Equipment DescriptionCertain components in this product and related Operate pressure washer only outdoorsContact with muffler area can result in serious burns Broken bones, fractures, bruises, or sprains could resultUnintentional sparking can result in fire or electric shock Risk of eye injury Spray can splash back or propel objects High pressure spray may damage fragile items including glassUnpack Pressure Washer AssemblyAttach Handle, Cleaning Tanks and Accessory Tray Items in the carton includeAdd Fuel Attach Detergent Siphon Hose to PumpAdd Engine Oil Fuel must meet these requirementsChecklist Before Starting Engine Connect Hose and Water Supply to PumpPump Develops high pressure Features and ControlsWater Inlet Connection for garden hose Pressure Washer Location How to Start Your Pressure WasherOperation Clearances and Air MovementBroken bones, fractures, bruises, or sprains could result Low Pressure How to Stop Your Pressure WasherHow to Use ProjectPro Nozzle System High PressureUsage Tips Applying DetergentTo apply detergent, follow these steps Automatic Cool Down System Thermal Relief Pressure Washer RinsingFor Rinsing Maintenance Schedule MaintenancePressure Washer Maintenance Ring Maintenance Check Detergent Siphoning Tube and Cleaning TanksNozzle Maintenance Check High Pressure HoseChecking Oil Level Engine MaintenanceOil Oil Recommendations Adding Engine OilService Spark Plug Service Air CleanerTo service the air cleaner, follow these steps Spark Arrester ServiceAfter Each Use You must protect your unit from freezing temperaturesTo protect the unit from freezing temperatures Winter StorageLong Term Storage Troubleshooting Problem Cause CorrectionOwner’s Warranty Responsibilities Emissions Control System WarrantyWarranties Emission Information MaintenanceClaims and Coverage Exclusions Limited Warranty Page Common Service Parts Product Specifications800 Manuel d’utilisation Moteur Où nous trouverNettoyeur à pression Date d’achatAssemblage Fonctions et commandes OpérationSécurité de l’opérateur EntretienDescription de l équipement Symboles de danger et moyensSécurité de l’opérateur Règles de sécuritéAvertissement Certains composants de ce produit ainsi que lesUnintentional peut résulter dans feu ou électrique Lorsque Vous Réglez OU Réparez Votre Nettoyeur À PressionAvis Les articles dans la boîte incluent AssemblageDéballage du nettoyeur à pression Remplissez et envoyez la carte d’enregistrementAjoutez de lhuile à moteur Fixez le tube de siphonnement du détergent à la pompeReplacez la jauge d’huile et serrez-la solidement ’essence satisfait les exigences suivantes Ajoutez de lessenceRaccorder le tuyau et la source deau à la pompe Évitez d’endommager le nettoyeur à pressionListe de vérifications avant de démarrer le moteur Fournissez de leau à une cadence appropriéeFonctions et commandes Mettre votre nettoyeur à pression en marche Emplacement de la nettoyeur à pressionOpération Dégagement de la nettoyeur à pressionUtilisez Toujours des lunettes de sécurité appropriées Comment utiliser le Système de buse ProjectPro Comment arrêter le nettoyeur à haute pressionHaute pression Basse pressionNoir Choisissez la buse ProjectPro vouluePour appliquer des produits détergents, procédez comme suit Application de détergentRincer le nettoyeur à pression Pour rincerCalendrier d’entretien EntretienEntretien du nettoyeur à pression Vérifiez le tube de siphonnement du détergent Vérifiez et nettoyez la grille de la prise deauVérifiez le tuyau à haute pression Entretien du gicleurVérification du niveau dhuile Huile Recommandations relatives à l’huileEntretien du moteur Ajout d’huileEntretien de la bougie dallumage Entretien du filtre à airEntretien du pare-étincelles Système de refroidissement à air Après chaque utilisationEntreposage pour lhiver Pour protéger lappareil contre le gelEntreposage à long terme Dépannage Garantie du dispositif antipollution GarantiesResponsabilités de la garantie du propriétaire Réclamations et exclusions de couverture Durée de la couvertureAucun frais EntretienGarantie Limitée Caractéristiques du produit Pièces d’entretien courant