Maintenance
4. | Slacken off two screws and remove the three |
|
| |
|
| |||
| others for the gear housing. Turn the gear housing |
|
| |
| so that the belts can be moved under the pulley. |
|
| |
5. | Check that the belt tensioning equipment is not |
|
| |
| jammed or binding and replace the spring. |
|
| |
6. | Position the new belt and reinstall the gear |
|
| |
| housing. |
|
| |
7. | Attach the new belt. |
|
| |
| The belt position decal is on the cutting unit under |
|
| |
| the protective cover. |
|
| |
8. | Install the protective covers. |
|
| |
Gearbox turned | ||||
9. | Attach the cutting unit to the machine. See “Side | |||
|
|
shifting the cutting unit” on page 45.
Removal of BioClip Plug
To change a Combi unit from the BioClip function to a cutting unit with rear ejection, remove the BioClip plug, which is located under the unit.
1.Put the unit in the service position. See “The Cutting Unit’s Service Position” on page 48.
2. | Remove the screws holding the BioClip plug, and |
|
| remove the plug. |
|
| Tip: Fit the fully threaded screws | Removal of BioClip Plug |
| M8x15 mm in the screw holes to protect the threads. |
|
3. | Return the unit to the normal position. |
|
Fit the BioClip plug in the reverse order.
52