Baldor 15H manuals
Computer Equipment > Electric Pencil Sharpener
When we buy new device such as Baldor 15H we often through away most of the documentation but the warranty.
Very often issues with Baldor 15H begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Electric Pencil Sharpener Baldor 15H is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Electric Pencil Sharpener on our side using links below.
123 pages 1.11 Mb
2 Table of Contents6 Quick Start Guide8 Section 212 Section 3 Receiving & Installation16 17 AC Main Circuit Power Disconnect Protective Devices 18 Receiving & Installation 3-7MN715Table 3-3 460VAC Controls (3 Phase) Wire Size and Protection Devices 3-8 Receiving & Installation MN715 19 Table 3-4 Receiving & Installation 3-9MN715 20 Figure 3-2 Series 15H ControlSee recommended Terminal Tightening Torques in Section 6. Table 3-5 Control Board Jumpers 21 AC Line ConnectionsFigure 3-3 Control Transformer Identification 22 Control Transformer Figure 3-4 Configuring the Control Transformer Terminal Block for 380 - 400VAC (Size G) * 3 Phase Installation Figure 3-5 3 Phase AC Power Connections3-12 Receiving & Installation MN715 sized from the 3 phase tables. 23 Table 3-6 Single Phase Rating Wire Size and Protection Devices - 230 VAC Controls*Table 3-7 Single Phase Rating Wire Size and Protection Devices - 460 VAC Controls* 24 Size A, B and B2 Single Phase Power InstallationFigure 3-6 Size A, B & B2 Single Phase 230/460VAC Power Connections 25 Size C2 Single Phase Power InstallationFigure 3-7 Figure 3-8 Size C2 Single Phase 230/460VAC Power Connections 26 Size C and D Single Phase Power InstallationFigure 3-9 Jumper Configuration Figure 3-10 Size C & D Single Phase 230/460VAC Power Connections 27 Figure 3-11 Jumper Configuration Figure 3-12 Size D2 Single Phase 230/460VAC Power Connections 28 Figure 3-13 Jumper ConfigurationFigure 3-14 Size E Single Phase 230/460VAC Power Connections 29 Figure 3-15 Jumper Configuration Figure 3-16 Size F Single Phase 230/460VAC Power Connections 30 Motor Brake Connections Motor Connections Figure 3-17 Motor Connections M-Contactor Figure 3-18 M-Contactor Diagram 3-20 Receiving & Installation MN715 31 Optional Dynamic Brake HardwareSee recommended Terminal Tightening Torques in Section 6. Electrical Installation Figure 3-19 DB Terminal Identification Figure 3-20 Wiring for RGA AssemblyE or W suffix EO or MO suffix ER suffixR2 B+/R1 B- GND DB Terminals Note: Although not shown, metal conduit should be used to shield all power wires and motor leads. Figure 3-21 Wiring for RBA Assembly Figure 3-22 Wiring for RTA AssemblySee recommended Terminal Tightening Torques in Section 6. DB Assembly See recommended Terminal Tightening Torques in Section 6. DB Assembly Note: Although not shown, metal conduit should be used to shield all power wires and motor leads. Receiving & Installation 3-21MN715 32 Table 3-8 Dynamic Brake Wire Size for RGA, RBA and RTA Assemblies33 Selection of Operating ModeFigure 3-23 Control Signal Connections 34 Figure 3-24 Analog Inputs 36 Keypad Operating ModeFigure 3-25 Keypad Control Connection Diagram3-26 Receiving & Installation MN715 37 Standard Run 3 Wire Operating ModeFigure 3-26 Standard Run 3-Wire Connection DiagramReceiving & Installation 3-27MN715 38 15 Speed 2-Wire Operating ModeFigure 3-27 15 Speed 2-Wire Control Connection Diagram Table 3-9 Switch Truth Table for 15 Speed, 2 Wire Control Mode3-28 Receiving & Installation MN715 39 Fan Pump 2 Wire Operating ModeFigure 3-28 Fan Pump, 2 Wire Control Connection Diagram Table 3-10 Speed Select Table Fan Pump, 2 WireReceiving & Installation 3-29MN715 40 Fan Pump 3 Wire Operating ModeFigure 3-29 Fan Pump, 3 Wire Control Connection Diagram Table 3-11 Speed Select Table Fan Pump, 3 Wire3-30 Receiving & Installation MN715 41 3 Speed Analog 2 Wire Operating ModeFigure 3-30 3 Speed Analog, 2 Wire Control Connection Diagram Table 3-12 Speed Select Table 3 Speed Analog, 2 WireReceiving & Installation 3-31MN715 42 3 Speed Analog 3 Wire Operating ModeFigure 3-31 3 Speed Analog, 3 Wire Control Connection Diagram Table 3-13 Speed Select Table 3 Speed Analog, 3 Wire3-32 Receiving & Installation MN715 43 Electronic Pot 2 Wire Operating ModeFigure 3-32 EPOT, 2 Wire Control Connection Diagram Table 3-14 Speed Select TableReceiving & Installation 3-33MN715 44 Electronic Pot 3 Wire Operating ModeFigure 3-33 EPOT, 3 Wire Control Connection Diagram 45 Process Operating ModeFigure 3-34 Process Mode Connection Diagram Table 3-15 Process Mode Input Signal Compatibility 46 External Trip Input Figure 3-35 Motor Temperature Relay Opto-Isolated Inputs Figure 3-36 Opto-Input Connections (Using Internal Supply)Section 1 General Information 3-36 Receiving & Installation MN715 47 Figure 3-37 Opto-Input Connections (Using External Supply)* * * Opto Inputs Closing to Ground Opto Inputs Closing to +VCC * * Digital Outputs Figure 3-38 Opto-isolated Output Configurations 48 Figure 3-39 Opto-Output Equivalent CircuitRelay Outputs Figure 3-40 Relay Output Connections 49 Pre-Operation Checklist Power Up Procedure 50 Section 4 Programming and Operation72 Section 5 Troubleshooting82 Section 6 Specifications and Product Data108 Appendix A114 Appendix B
Also you can find more Baldor manuals or manuals for other Computer Equipment.