Troubleshooting 5-3MN715
How to Access the Fault Log When a fault condition occurs, motor operation stops and a fault code is displayed on
the Keypad display. The control keeps a log of the last 31 faults. If more than 31 faults
have occurred, the oldest fault will be deleted from the fault log. To access the fault log,
perform the following procedure:
Action Description Display Comments
Apply Power Logo display for 5 seconds.
Display mode showing Local
mode, voltage, current &
frequency status.
No faults present. Local keypad
mode. If in remote/serial mode,
press local for this display.
Press DISP key Press DISP to scroll to the Fault
Log entry point.
Press ENTER key Display first fault type and time
fault occurred. Typical display.
Press key Scroll through fault messages. If no messages, the fault log exit
choice is displayed.
Press RESET key Return to display mode. Display mode stop key LED is on.
How to Clear the Fault Log Use the following procedure to clear the fault log.
Action Description Display Comments
Apply Power Logo display for 5 seconds.
Display mode showing Local
mode, voltage, current &
frequency status.
Display mode.
Press DISP key Press DISP to scroll to the Fault
Log entry point.
Press ENTER key Displays most recent message.
Press SHIFT key
Press RESET key
Press SHIFT key
Press ENTER key Fault log is cleared. No faults in fault log.
Press or key Scroll Fault Log Exit.
Press ENTER key Return to display mode.