Section 1
General Information

Appendix B-3MN715

Table B-1 Parameter Block Values Level 1 Continued
Level 1 Blocks - Continued
Block Title Parameter P# Adjustable Range Factory User
Setting
OUTPUT
(Continued) ANALOG OUT #1 1508 0Frequency
1Freq Command
2AC Current
3AC Voltage
4Torque (Load)
Frequency
ANALOG OUT #2 1509 5Power
6Bus Voltage
7Process Fdbk
8Setpoint Cmd
9Zero Cal
10100% Cal
AC Current
ANALOG #1 SCALE 1510 10 - 160% 100.0%
ANALOG #2 SCALE 1511 10 - 160% 100.0%
OVERLOAD SP 1512 0.00 to 100.00% 50.00%
UNDERLOAD SP 1513 0.00 to 100.00% 50.00%
V/HZ AND BOOST CTRL BASE
FREQUENCY 1601 50.00 - 400.00Hz 60.0Hz
TORQUE BOOST 1602 0.0 - 15.0% 2.5%
DYNAMIC BOOST 1603 0.0 - 100% 0.0%
SLIP COMP ADJ 1604 0.00 - 6.00Hz 0.00Hz
V/HZ PROFILE 1605 0LINEAR,
133% SQR LAW,
267% SQR LAW,
3100% SQR LAW
43 POINTS
Linear
V/HZ 3PT VOLTS 1606 0-100% 0.0%
V/HZ 3PT FREQUENCY 1607 0-9.99Hz 0.00Hz
MAX OUTPUT VOLTS 1608 0-100 100.0%
LEVEL 2 BLOCK ENTERS LEVEL 2 MENU - See Table B-2.
PRESS ENTER FOR
PROGRAMMING EXIT
Exit programming mode and return to display mode.