Optional Remote Keypad Installation The keypad may be remotely mounted using optional Baldor keypad extension cable. Keypad assembly (white - DC00005A-01; gray - DC00005A-02) comes complete with the screws and gasket required to mount it to an enclosure. When the keypad is properly mounted to a NEMA Type 4X enclosure, it retains the Type 4X rating.

Tools Required:

Center punch, tap handle, screwdrivers (Phillips and straight) and crescent wrench.

8-32 tap and #29 drill bit (for tapped mounting holes) or #19 drill (for clearance mounting holes).

1-1/4standard knockout punch (1-11/16nominal diameter).

RTV sealant.

(4) 8-32 nuts and lock washers.

Extended 8-32 screws (socket fillister) are required if the mounting surface is thicker than 12 gauge and is not tapped (clearance mounting holes).

Remote keypad mounting template. A tear out copy is provided at the end of this manual for your convenience. (Photo copy or tear out.)

Mounting Instruction:

For tapped mounting holes

 

1.

Locate a flat 4wide x 5.5minimum high mounting surface. Material should

 

 

be sufficient thickness (14 gauge minimum).

 

2.

Place the template on the mounting surface or mark the holes as shown.

 

3.

Accurately center punch the 4 mounting holes (marked A) and the large

 

 

knockout (marked B).

 

4.

Drill four #29 mounting holes (A). Thread each hole using an 8-32 tap.

 

5.

Locate the 1-1/4knockout center (B) and punch using the manufacturers

 

 

instructions.

 

6.

Debur knockout and mounting holes making sure the panel stays clean and flat.

 

7.

Apply RTV to the 4 holes marked (A).

 

8.

Assemble the keypad to the panel. Use 8–32 screws, nuts and lock washers.

 

9.

From the inside of the panel, apply RTV over each of the four mounting screws

 

 

and nuts. Cover a 3/4area around each screw while making sure to completely

 

 

encapsulate the nut and washer.

Mounting Instructions:

For clearance mounting holes

 

1.

Locate a flat 4wide x 5.5minimum high mounting surface. Material should

 

 

be sufficient thickness (14 gauge minimum).

 

2.

Place the template on the mounting surface or mark the holes as shown on the

 

 

template.

 

3.

Accurately center punch the 4 mounting holes (marked A) and the large

 

 

knockout (marked B).

 

4.

Drill four #19 clearance holes (A).

 

5.

Locate the 1-1/4knockout center (B) and punch using the manufacturers

 

 

instructions.

 

6.

Debur knockout and mounting holes making sure the panel stays clean and flat.

 

7.

Apply RTV to the 4 holes marked (A).

 

8.

Assemble the keypad to the panel. Use 8–32 screws, nuts and lock washers.

 

9.

From the inside of the panel, apply RTV over each of the four mounting screws

 

 

and nuts. Cover a 3/4area around each screw while making sure to completely

encapsulate the nut and washer.

MN715

Receiving & Installation 3-3

Page 14
Image 14
Baldor 15H, Inverter Control manual Tools Required, Mounting Instruction For tapped mounting holes

Inverter Control, 15H specifications

The Baldor 15H Inverter Control stands out as a leading solution in the realm of variable frequency drives (VFDs), specifically designed for enhancing motor efficiency and performance in industrial applications. This control unit is engineered to provide robust and reliable performance while ensuring seamless integration with various motor types.

One of the main features of the Baldor 15H is its advanced control algorithms, which facilitate precise motor control. This technology allows for smooth acceleration and deceleration, reducing mechanical stress on the system and extending the lifespan of both the motor and connected equipment. The inverter control is adept at handling both synchronous and asynchronous motors, making it highly versatile for different operational needs.

The Baldor 15H incorporates a user-friendly interface that provides operators with real-time data and diagnostics. This feature allows for easy monitoring and troubleshooting, helping to minimize downtime and maintenance costs. The intuitive control panel simplifies parameter adjustments, enabling quick customization for specific application requirements.

Safety is paramount in industrial environments, and the Baldor 15H includes several safety features designed to protect both the equipment and personnel. These features include overload protection, overvoltage protection, and short-circuit protection, ensuring reliable operation even under demanding conditions.

Energy efficiency is another critical aspect of the Baldor 15H. By utilizing pulse-width modulation (PWM) technology, it optimizes power usage, which translates to lower energy costs and reduced environmental impact. This makes it an excellent choice for companies aiming to improve their sustainability practices.

Moreover, the Baldor 15H supports a variety of communication protocols, allowing for easy integration into existing automation systems. This capability ensures that operators can utilize the inverter control within modern industrial networks, enhancing overall system efficiency.

In terms of physical characteristics, the Baldor 15H is designed for durability and reliability. It comes with a robust enclosure that protects against dust, moisture, and other environmental factors commonly found in industrial settings. Its compact design also allows for easy installation in limited spaces.

Overall, the Baldor 15H Inverter Control is a comprehensive solution that combines advanced technology, safety features, and energy efficiency, making it a preferred choice for industries looking to optimize their motor control systems. Its adaptability to different motor types and integration capabilities further solidify its position as a leader in VFD technology.