Parameter Definitions (Version S15H–5.06)

 

LEVEL 1 BLOCKS

LEVEL 2 BLOCKS

Preset Speeds

Input

Output Limits

Brake Adjust

Preset Speed #1

Operating Mode

Operating Zone

Resistor Ohms

Preset Speed #2

Command Select

Min Output Frequency

Resistor Watts

Preset Speed #3

ANA CMD Inverse

Max Output Frequency

DC Brake Voltage

Preset Speed #4

ANA CMD Offset

PK Current Limit

DC Brake Frequency

Preset Speed #5

ANA CMD Gain

REGEN Limit

Brake on Stop

Preset Speed #6

CMD SEL Filter

REGEN Limit ADJ

Brake on Reverse

Preset Speed #7

Power Up Mode

PWM Frequency

Stop Brake Time

Preset Speed #8

 

 

Brake on Start

Preset Speed #9

Output

Custom Units

Start Brake Time

Preset Speed #10

Digital Out #1

MAX Decimal Places

 

Preset Speed #11

Digital Out #2

Value at Speed

Process Control

Preset Speed #12

Digital Out #3

Value DEC Places

Process Feedback

Preset Speed #13

Digital Out #4

Value Speed REF

Invert Feedback

Preset Speed #14

Zero SPD Set PT

Units of Measure

Setpoint Source

Preset Speed #15

At Speed Band

Units of MEAS 2

Setpoint Command

 

Set Speed Point

 

Set PT ADJ Limit

Accel / Decel Rate

Analog Out #1

Protection

At Setpoint Band

Accel Time #1

Analog Out #2

External Trip

Process PROP Gain

Decel Time #1

Analog Scale #1

Local Enable INP

Process INT Gain

S-Curve #1

Analog Scale #2

I2T Response

Process DIFF Gain

Accel Time #2

Overload SP

I2T Trigger

Follow I:O Ratio

Decel Time #2

Underload SP

Peak CUR Timer

Follow I:O Out

S-Curve #2

 

Foldback Gain

Encoder Lines

 

 

 

Integrator Clamp

Jog Settings

V/HZ and Boost

Miscellaneous

Minimum Speed

Jog Speed

Ctrl Base Frequency

Restart Auto/Man

Process Type

Jog Accel Time

Torque Boost

Restart Fault/Hr

 

Jog Decel Time

Dynamic Boost

Restart Delay

Skip Frequency

Jog S-Curve

Slip Comp Adj

Factory Settings

Skip Frequency #1

 

V/HZ Profile

Language Select

Skip Band #1

Keypad Setup

V/HZ 3-PT Volts

STAB Cutoff Freq

Skip Frequency #2

Keypad Stop Key

V/HZ 3-PT Frequency

Stability Gain

Skip Band #2

Keypad Stop Mode

Max Output Volts

 

Skip Frequency #3

Keypad Run Fwd

 

Security Control

Skip Band #3

Keypad Run Rev

 

Security State

 

Keypad Jog Fwd

 

Access Timeout

Synchro Starts

Keypad Jog Rev

 

Access Code

Synchro Starts

3 Speed Ramp

 

 

Sync Start Frequency

Switch on Fly

 

Motor Data

Sync Scan V/F

LOC. Hot Start

 

Motor Voltage

Sync Setup Time

Keypad SPD INC

 

Motor Rated Amps

Sync Scan Time

 

 

Motor Rated Speed

Sync V/F Recover

 

 

Motor Rated Frequency

Sync Direction

 

 

Motor Mag Amps

 

 

 

 

Communications

 

 

 

Protocol

 

 

 

Baud Rate

 

 

 

Drive Address

 

 

 

 

4-12 Programming & Operation

MN715

Page 61
Image 61
Baldor Inverter Control manual Parameter Definitions Version S15H-5.06

Inverter Control, 15H specifications

The Baldor 15H Inverter Control stands out as a leading solution in the realm of variable frequency drives (VFDs), specifically designed for enhancing motor efficiency and performance in industrial applications. This control unit is engineered to provide robust and reliable performance while ensuring seamless integration with various motor types.

One of the main features of the Baldor 15H is its advanced control algorithms, which facilitate precise motor control. This technology allows for smooth acceleration and deceleration, reducing mechanical stress on the system and extending the lifespan of both the motor and connected equipment. The inverter control is adept at handling both synchronous and asynchronous motors, making it highly versatile for different operational needs.

The Baldor 15H incorporates a user-friendly interface that provides operators with real-time data and diagnostics. This feature allows for easy monitoring and troubleshooting, helping to minimize downtime and maintenance costs. The intuitive control panel simplifies parameter adjustments, enabling quick customization for specific application requirements.

Safety is paramount in industrial environments, and the Baldor 15H includes several safety features designed to protect both the equipment and personnel. These features include overload protection, overvoltage protection, and short-circuit protection, ensuring reliable operation even under demanding conditions.

Energy efficiency is another critical aspect of the Baldor 15H. By utilizing pulse-width modulation (PWM) technology, it optimizes power usage, which translates to lower energy costs and reduced environmental impact. This makes it an excellent choice for companies aiming to improve their sustainability practices.

Moreover, the Baldor 15H supports a variety of communication protocols, allowing for easy integration into existing automation systems. This capability ensures that operators can utilize the inverter control within modern industrial networks, enhancing overall system efficiency.

In terms of physical characteristics, the Baldor 15H is designed for durability and reliability. It comes with a robust enclosure that protects against dust, moisture, and other environmental factors commonly found in industrial settings. Its compact design also allows for easy installation in limited spaces.

Overall, the Baldor 15H Inverter Control is a comprehensive solution that combines advanced technology, safety features, and energy efficiency, making it a preferred choice for industries looking to optimize their motor control systems. Its adaptability to different motor types and integration capabilities further solidify its position as a leader in VFD technology.