GE GFK-0825F manuals
Household Appliance > Carbon Monoxide Alarm
When we buy new device such as GE GFK-0825F we often through away most of the documentation but the warranty.
Very often issues with GE GFK-0825F begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Carbon Monoxide Alarm GE GFK-0825F is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Carbon Monoxide Alarm on our side using links below.
248 pages 1.54 Mb
2 Warnings, Cautions, and Notes as Used in this Publication3 PrefaceContent of this Manual 4 PrefaceRelated Publications 5 Contents10 Introduction22 Description31 Installation48 Operation49 BIU Data Handling at the I/O Station 52 The BIU Sweep1 BIU Reads Inputs from Conventional Modules 2 BIU Reads All Input Reference Parameters 3 BIU Reads Group Data Whose Destination is BIU 4 BIU Sends Group Data to Synchronization Module 5 BIU Sends Reference Parameters to a Synchronization Module 54 BIU Backplane Scan TimeExample 1: 55 Example 2:Five modules, one Group Data Move. Genius bus speed is 26mS. 56 Data Transfer Between the BIU and the HostData in the BIU's Network (Bus) Map Communications on the Genius Bus 57 Input Data Sent by the Bus Interface Unit59 Genius Bus Scan TimeProcedure for Estimating Bus Scan Time for a Field Control Station 60 Throughput61 Operation of the BIU with a Micro Field Processor68 Station ConfigurationFor Additional Information, Also See: 69 Configuring the Serial Bus Address and Baud RateSpecial Instructions for Series 90-70 PLC Systems 70 Set Up the Hand-held Monitor2. Begin with the HHM turned off. Attach it to the connector on the Bus Interface Unit. 3. Tur n the Hand-held Monitor on. Adjust its baud rate if necessary. F1:HHM UTILITIES F2:ANALYZE F3:CONFIGURATION F4:DEVICE MEMORY 71 Create a New ConfigurationAssigning a Serial Bus Address to a New BIU 72 Configure the Bus Interface Unit82 Configure Field Control ModulesEnable/Disable the I/O Sca Disable Network I/O Update 83 Configure the Network Map for the Bus Interface UnitBlk Map Start I ? 84 Configuring Extra References in the BIU I/O MapExample 87 Add Modules and Assign References S:1 Empty < > tgl readIf the slot has previously been configured, the HHM shows the existing configuration. For exam ple: S:1 Q:16 Q01785-Q01800 < > del zoomSee the instructions on th e next two pages to configure th e slot.Module Present, Read/Zoom to configure: Module Present, Read/En te r to configure, or No Module Present , Select Special I/O to configure: No Module Present , Select Generic I/O to configure: 88 Configuration with No Module PresentRead a Module Identification with the Module Present Delete an Existing Module Configuration 89 Configure a Discrete Input ModuleS:1 I:16 I tgl entr S:1 I:16 I00001- I00016 90 Default Inputs or Hold Last State91 Configure a Discrete Output Module92 Default Outputs or Hold Last State93 Configure a Discrete Input/Output ModuleAssign I/O References 94 Default Inputs or Hold Last State95 Default Outputs or Hold Last State96 Configure a Conventional Analog Input Module97 Channel Fault ReportingS1 Faults Ch 01 YYYYYYYY S1 Active Ch 01 YYYYYYYY 98 Input Current Ranges99 Input Scaling101 Default Inputs or Hold Last Values102 Configure a Conventional Analog Output Module103 Default Outputs or Hold Last ValuesOutput Default Values 104 Channel Fault ReportingS1 Faults Ch 01 NNYY S1 Active Ch 01 NYYN 105 Output Current Ranges106 Output ScalingS1 Scale 1 Ch 015-40 Field Control Genius Bus Interface Unit Users Manual October 1999 GFK-0825F 107 Configure a 16-Point Grouped Analog Input ModuleDefault data length When you select Read fr om the empty slot HHM screen, thi s module screen appears: S:4 ALG240 1.0When you "zoom" into the mod u l e's slot, a screen like this ap p ear s: S:4 AI *AI:016 AI01307-01322 < > chg entr 115 Configure an 8-Point Grouped Analog Voltage Input Module123 Configure a 16-Point Grouped Analog Voltage Input ModuleS:2 AI AI tgl entr S:2 AI AI:016 clr entr 129 S:2 CH1 ENG LO -100005-64 Field Control Genius Bus Interface Unit Users Manual October 1999 GFK-0825F 131 Configure an RTD Input Module When you select Read from the empty slot HHM screen, this module screen appears: S:4 ALG620 *.*Module version Press F4 to zoom into the slot. A screen like this appears:Number of references for this module type S:4 AI *AI:004 AI01311-01314 chg entr S:4 AI AI:004 chg entr 133 Line Frequency136 RTD TypeS:1 CH1 RTD TYPE 100 PT 385 Wire Type 137 Low Alarm LimitHigh Alarm Limit 138 ResistanceS:1 RESIST.1 000005-72 Field Control Genius Bus Interface Unit Users Manual October 1999 GFK-0825F 139 Configuring a Thermocouple Input Module When you select Read from the empty slot HHM screen, this module screen appears: S:4 ALG630 *.*Press F4 to zoom into the slot. A screen like this appears:Number of references for this module type S:4 AI *AI:008 AI00009-00016 tgl entr S:4 AI AI:008 clr entr 144 S:1 CH1 TC TYPE NONES:1 CH1 RANGE TP 625 148 Configure an 8-Point Analog Voltage Output ModuleS:1 ALG310 1.0 S:1 I * I:024 I00257-I00280 152 Configure Local Default Outputs154 Scaling RangeS:1 CH1 RANGE -10V TO +10V 157 Configure an 8-Point Analog Current Output ModuleAssign I/Assign I/O References for the Module 161 Configure Local Default Outputs163 Scaling Range164 Output ScalingCustom Scaling S:1 CH1 ENG L 04000 S:1 CH1 ENG H 20000 166 Configure a Micro Field ProcessorConfigure the Reference Parameters for the Micro Field ProcessorF1 Monitor F2 Configuration S:1 EMPTY tgl read S7: MFP1.0 167 Select Data Types for Micro Field Processor Data169 Configure Group Data Moves Group Data Moves Worksheet 170 Set Up a Group Data Move174 Deleting a Group Data Move175 Diagnostics and Fault Clearing180 Monitoring and Controlling Field Control Data187 DatagramsScaling Analog Channels 220 A225 B227 C238 D
Also you can find more GE manuals or manuals for other Household Appliance.