VXI VT1538A manuals
Musical Instruments & Equipment > DJ Equipment
When we buy new device such as VXI VT1538A we often through away most of the documentation but the warranty.
Very often issues with VXI VT1538A begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in DJ Equipment VXI VT1538A is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for DJ Equipment on our side using links below.
84 pages 2.4 Mb
VT1538A ENHANCED FREQUENCY/TOTALIZE/ PWM SIGNAL CONDITIONING PLUG-ON USERS MANUAL 3 INTRODUCTION Agilent Technologies E1538A Enhanced Frequency/Totalize/PWM Signal Conditioning Plug-onUsers and SCPI Programming Manual 5 7 Agilent E1538A Enhanced Frequency/Totalize/PWM SCPAbout this Manual 8 Introduction9 Identifying the Plug-on (IMPORTANT)10 Setting Configuration Switches12 Recommended Signal Connections13 Input and Output Characteristics15 Programming With SCPI CommandsChecking the ID of the SCP 16 Configuring theConfiguring I/O Direction Programming InputSetting the Input Threshold Level 17 Determining the Input Threshold Level Note 24 Sense Quadrature Position 25 27 34 41 46 SCPI Command ReferenceINPut:POLarityComments If the channels specified are on an SCP that doesn t support this function, 48 Usage INPut:POLarity?Comments <channel> must specify a single channel. INPut:THReshold[:LEVel]Comments <level> can be set to a resolution of .375V 49 INPut:THReshold[:LEVel]?Comments <channel> must specify a single channel. Note 50 Usage OUTPut:POLarityComments If the channels specified do not support this functi on, an error will be Usage OUTPut:POLarity?Comments Channel must specify a single channel 51 [SENSe:]FREQuency:APERtureComments For APERture to effect the measurement, SENS:FREQ:MODE must be Usage [SENSe:]FREQuency:APERture?Comments If the channel specified is on an SCP that doesn t support this fun ction, 52 SENSe:FREQuency:LIMit:LOWer 53 SENSe:FREQuency:LIMit:LOWer? 54 [SENSe:]FUNCtion:CONDitionComments The E1538 SCP senses the single bit digital state on each channel Usage [SENSe:]FUNCtion:FREQuencyComments If the channels specified are on an SCP that doesn t support this function, 55 Usage [SENSe:]FUNCtion:PERiodComments If the channels specified are on an SCP that doesn t support this function, 56 Usage [SENSe:]FUNCtion:PWIDth Usage [SENSe:]FUNCtion:QUADratureComments <count_preset> if included, allows presetting the absolute counter 57 Usage [SENSe:]FUNCtion:RVELocityComments This function can only be linked to the E1538s first channel. The 58 Usage SENSe:]FUNCtion:TOTalizeComments The totalize function counts rising edges of digital transitions at 59 Usage [SENSe:]PERiod:APERtureComments The range for <aperture> is dependent on SENS:PER:RANGE: 60 Usage [SENSe:]PERiod:APERture?Comments If the channel specified is on an SCP that doesn t support this fun ction, 61 62 [SENSe:]PERiod:LIMit:UPPer? 63 SENSe:PERiod:MODEComments The SENS:PER:APERture command sets the aperture value. The SENSe:PERiod:MODE?interval mode currently set for period measurement. 64 SENSe:PERiod:NPERiodssignal periods to measure and average in order to compute the input signal period. SENSe:PERiod:NPERiods?signal periods the SCP will measure and average to calculate the signal period. Comments <channel> must be single channel on an E1538A SCP. 65 [SENSe:]PERiod:RANGe[:UPPer] 66 [SENSe:]PERiod:RANGe[:UPPer]?Comments <channel> must be single channel on an E1538A SCP. [SENSe:]TOTalize:RESet:MODEComments In the INIT mode the total is reset only when the INIT iate command i s 67 Usage [SENSe:]TOTalize:RESet:MODE?Comments Channel must specify a single channel. SOURce:FM[:STATe]Comments This command is coupled with the SOURce:PULM:STATE command. SOURce:FUNCtion:RPULseComments <ref_channel> must be a single channel and must be the first channel 69 Notes Usage 70 SOURce:FUNCtion[:SHAPe]:CONDitionComments The E1533 SCP sources 8 digital bits on the channel specified by this SOURce:FUNCtion[:SHAPe]:PULSeComments This PULSe channel function is further defined by the 71 SOURce:FUNCtion[:SHAPe]:SQUareComments Send with VXIplug&play Function: hpe14XX_cmd(...) Usage SOURce:FUNCtion:STEPperComments <preset_pos> defines the position count at algorithm start-up. This is an 73 Usage SOURce:PULM[:STATe]Comments This command is coupled with the SOURce:FM command. If the FM 74 SOURce:PULSe:PERiodComments If the channels specified are not on a Frequency/Tota lize SCP, an error Usage SOURce:PULSe:PERiod?Comments If the channels specified are not on a Frequency/Tota lize SCP, an error 75 SOURce:PULSe:WIDThComments If the channels specified are not on a Frequency/Tota lize SCP, an error Usage SOURce:PULSe:WIDTh?Comments Channel must specify a single channel. 76 SOURce:RPULse:POSition[:ANGLe]Comments Channels in <ch_list> must be referenced in a SOUR:FUNC:RPUL Usage SOURce:RPULse:POSition[:ANGLe]?Comments <channel> must specify a single channel only Usage SOUR:RPULse:VARTypeComments <type> specifies the that the algorithm will send values of either: 77 Usage SOUR:RPULse:VARType?Comments <ch_list> must specify a single channel only 78 Usage SOURce:RPULse:WIDTh[:ANGLe]Comments Channels in <ch_list> must be referenced in a SOUR:FUNC:RPUL Usage SOURce:RPULse:WIDTh[:ANGLe]?Comments <channel> must specify a single channel only. Usage SOURce:RPULse:WIDTh:TIMEComments Channels in <ch_list> must be referenced in a SOUR:FUNC:RPUL 79 Usage 80 SOURce:RPULse:WIDTh:TIME?channel rotational output pulse currently set for <channel>. Comments <channel> must specify a single channel only. Usage 81 SpecificationsThese specifications for the E1538A reflect its performance while instal le d on your VXI module. General Specifications
Also you can find more VXI manuals or manuals for other Musical Instruments & Equipment.