VXI VT1538A user manual SENSeFUNCtionFREQuency, SENSeFUNCtionPERiod, Parameters

Models: VT1538A

1 84
Download 84 pages 24.07 Kb
Page 55
Image 55
[SENSe:]FUNCtion:FREQuency

SENS:FUNC:COND (@144:147)

[SENSe:]FUNCtion:FREQuency

[SENSe:]FUNCtion:FREQuency <ch_list> sets the SENSe function to

frequency for channels in <ch_list>. Also configures the channels specified

as digital inputs. See “About Period and Frequency Measurements” on page 16.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

ch_list

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments If the channels specified are on an SCP that doesn’t support this function, an error will be generated. See your SCP’s User’s Manual for its capabilities.

Related commands: SENS:FREQ:APER, SENS:FREQ:MODE

*RST Condition: SENS:FUNC:COND and INP:POL NORM for all digital SCP channels

Send with VXIplug&play Function: hpe14XX_cmd(...)

Usage See “About Period and Frequency Measurements” on page 16.

SENS:FUNC:FREQ (@144)

[SENSe:]FUNCtion:PERiod

[SENSe:]FUNCtion:PERiod (@<ch_list>) sets the SENSe function to period for channels in <ch_list>. Also configures the channels specified as

digital inputs. See “About Period and Frequency Measurements” on page 16.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

ch_list

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments If the channels specified are on an SCP that doesn’t support this function, an error will be generated. See your SCP’s User’s Manual for its capabilities.

Related commands: SENS:PER:APER, SENS:PER:NPER,