VXI VT1538A SENSePERiodMODE?, SENSePERiodNPERiods, Related Commands SENSePERiodMODE, Parameters

Models: VT1538A

1 84
Download 84 pages 24.07 Kb
Page 64
Image 64
SENSe:PERiod:MODE?
<ch_list> must be channels on an E1538A SCP.

SENSe:PERiod:MODE?

SENSe:PERiod:MODE? (@<channel>) returns the measurement

interval mode currently set for period measurement.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

channel

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments

SENSe:PERiod:NPERiods

<channel> must be a single channel on an E1538A SCP.

RETURNS: String value "APER" or "NPER", Type is String

.Send with VXIplug&play Function: hpe14XX_cmdString_Q(...)

SENSe:PERiod:NPERiods <count>,(@<ch_list>) sets the number of

signal periods to measure and average in order to compute the input signal period.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

count

numeric (uint32)

1 to 255 MINimum MAXimum

seconds

 

 

 

 

 

 

 

 

ch_list

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments

This feature is only available when the NPERiods period mode is in use: SENSe:PERiod:MODE NPERiods,<ch_list>

Related Commands: SENSe:PERiod:MODE

RESET Condition: is “MINimum” (i.e. 1).

.Send with VXIplug&play Function: hpe14XX_cmd(...)

60 Agilent E1538A Enhanced Frequency/Totalize/PWM SCP