INPut:POLarity
<channel> must specify a single channel.

INPut:POLarity

INPut:POLarity <mode>,<ch_list> sets logical input polarity on a digital

SCP channel.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

mode

discrete (string)

NORMal INVerted

none

 

 

 

 

 

 

 

 

ch_list

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments If the channels specified are on an SCP that doesn’t support this function, an error will be generated. See your SCP’s User’s Manual to determine its capabilities.

Related Commands: for output sense; SOURce:PULSe:POLarity

*RST Condition: INP:POL NORM for all digital SCP channels.

Send with VXIplug&play Function: hpe14XX_cmd(...)

Usage INP:POL INV,(@140:143)

invert first 4 channels on SCP at

 

SCP position 5. Channels 40

 

through 43

INPut:POLarity?

INPut:POLarity? <channel> returns the logical input polarity on a digital

SCP channel.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

channel

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments

If the channel specified is on an SCP that doesn’t support this function, an error will be generated. See your SCP’s User’s Manual to determine its capabilities.

Returned Value: returns "NORM" or "INV". The type is string.

Send with VXIplug&play Function: hpe14XX_cmdString_Q(...)