SENSe:FREQuency:LIMit:LOWer?
[SENSe:]FREQuency:LIMit:LOWer? <channel> returns the lower frequency limit currently set for <channel>
Parameters
|
|
|
|
|
|
| Parameter | Parameter | Range of | Default |
|
| Name | Type | Values | Units |
|
|
|
|
|
|
|
| channel | string | 100 - 163 | none |
|
|
|
|
|
|
|
|
|
|
|
|
|
Comments •
•
•
<channel> must be a single channel on an E1538A SCP.
Returned Value: .01667 to 250, The type is float32.
Send with VXIplug&play Function: hpe14XX_cmdReal64_Q(...)
[SENSe:]FUNCtion:CONDition
[SENSe:]FUNCtion:CONDition <ch_list> sets the SENSe function to input the digital state for channels in <ch_list>. See “Reading Static Digital State” on page 14.
Parameters
|
|
|
|
|
|
| Parameter | Parameter | Range of | Default |
|
| Name | Type | Values | Units |
|
|
|
|
|
|
|
| ch_list | string | 100 - 163 | none |
|
|
|
|
|
|
|
|
|
|
|
|
|
Comments • The E1538 SCP senses the single bit digital state on each channel specified by this command.
•If the channels specified are not on a digital SCP, an error will be generated.
•Use the INPut:POLarity command to set input logical sense.
•Related Commands: INPut:POLarity
•*RST Condition: SENS:FUNC:COND and INP:POL NORM for all digital SCP channels.
•Send with VXIplug&play Function: hpe14XX_cmd(...)
Usage See “Reading Static Digital State” on page 14.
To set upper