VXI VT1538A SENSeFREQuencyAPERture?, SENSeFREQuencyLIMitLOWer, Related Commands SENSFREQAPER

Models: VT1538A

1 84
Download 84 pages 24.07 Kb
Page 52
Image 52
[SENSe:]FREQuency:APERture?

[SENSe:]FREQuency:APERture?

[SENSe:]FREQuency:APERture? <channel> returns the currently set APERture time.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

channel

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments If the channel specified is on an SCP that doesn’t support this function, an error will be generated. See your SCP’s User’s Manual for its capabilities.

Related Commands: SENS:FREQ:APER

Returned Value: returns numeric aperture in seconds, The type is float32.

Send with VXIplug&play Function: hpe14XX_cmdReal64_Q(...)

SENSe:FREQuency:LIMit:LOWer

[SENSe:]FREQuency:LIMit:LOWer <freq_limit>,<ch_list> allows you to specify a frequency lower limit beyond which the E1538A will stop waiting for a signal transition and will return a frequency value of zero. Conceptually, this is an input signal period time-out.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

freq_limit

numeric (float32)

.01667 to 250

Hz

 

 

 

 

 

 

 

 

ch_list

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments <ch_list> must be channels on an E1538A SCP.

Note Although SENS:FREQ:LIM:LOW can set a "timeout period" as long as 60 seconds (.01667Hz), the lowest frequency measurement supported by the E1538A is 1 Hertz.

The period associated with the FREQ:LIMit:LOWer frequency is the time the SCP will allow for any single cycle period.

At any time during the frequency measurement, if the signal’s period

48 Agilent E1538A Enhanced Frequency/Totalize/PWM SCP

Page 52
Image 52
VXI VT1538A user manual SENSeFREQuencyAPERture?, SENSeFREQuencyLIMitLOWer, Related Commands SENSFREQAPER, Parameters