Configuring IGMP Snooping Parameters 3-11

3View the status of IGMP snooping on a vbridge configured on the ATM backbone SwitchModule.

For example, the following command displays the status of IGMP snooping on vbridge 1 on the ATM Backbone SwitchModule in slot 9:

CB5000> show vbridge 1 igmp_snooping status

4Save the parameter changes you made.

For example, the following command saves the parameter changes you made to the ATM Backbone SwitchModule in slot 9:

CB5000> save all

This command only saves the parameter changes in RAM. To actually effect the changes on the ATM Backbone SwitchModule, you must reset the module.

5Reset the ATM Backbone SwitchModule to enable IGMP snooping on the SwitchModule and the vbridge.

For example, the following command resets the ATM Backbone SwitchModule in slot 9, thus enabling IGMP snooping on the SwitchModule and vbridge 1:

CB5000> reset module 9.1

CAUTION: Do not use the RESET HUB command in this instance. Parameters saved in NVRam may not get updated if you use the RESET HUB command. Use only the RESET MODULE command in this instance.