described below. Afterwards, return the card to its slot in the original chassis.
Downloading The CoreBuilder 7000 allows you to upload selected types of
Selected Data Types configuration data. The types of configuration data you can upload depends on the card you selected. For the switch card, the types of configuration data you can upload are as follows:
All Configuration Data
Platform Parameters
ATM Addresses
PNNI Configuration
LANE Security
PVC Connections
LECS Topology
LECS Order List
For a CoreBuilder 7X00 card, the data types are as follows:
Platform Parameters Static
Organizing The uploaded configuration files can be named using a naming Configuration Files convention of your choice. Normally, you will want to include information
about the data type, the card type and a date or other identifier in the file name. For example, you might use file names like cfg_7000_12jun98 and static_7600_1.
When you download configuration data from the files on the disk to the card, you designate the card by its slot number. The slot can contain the original card from which the data was uploaded, or it can contain another card of the same type.
If you try to download configuration data which was uploaded from one type of card type to another type of card, an appropriate error message is issued.
Activating the When the configuration files are downloaded into flash memory, they Downloaded overwrite the previous information. The new parameters are not Configuration activated immediately, but rather after the next reboot when they are