Loading Software and Configuration Data by Batch Utilities
dPress Enter
eChoose desired option at a prompt(s) (if at all)
Returning to After the software has been stored or retrieved, the system will still be in Operational Mode load mode. To return the system to normal operational mode, use one of
the following methods.
Method 1 - Shift “O”
1Reboot the switch
2Within 3 seconds of rebooting press Shift “O”
3Perform the menu item
(1)SYS \(3) LOA \ (3) LCL \ 0
The system is now in operational mode.
Method 2 - dbgoff.bat
1Run the batch file dbgoff.bat: a Type dbgoff.bat
b Type the appropriate ComPort switch (com1/com2)
c Type the appropriate Speed switch (19200/57600/115200) d Press Enter
e Wait for completion
2Reboot the switch