![Power Supply 90A AC Power Supply](/images/new-backgrounds/178178/178178185x1.webp)
Redundant Power Supply
The light load installation is illustrated by the fourth example installation in Table
In all installations that do not include multiple CB7600 cards both redundant switch cards and redundant power supplies can be installed.
Power Supply 90A AC Power Supply |
|
|
| ||
Specifications | CoreBuilder 7000 (3C37010A) | Enhanced Power Supply Specifications | |||
| Table | ||||
|
|
|
|
| |
| Parameter |
| Channel 1 | Channel 2 | |
| Nominal output voltage (V) | 5 |
| 12 | |
| Output voltage range (V) | 5 +/- 5% | 12 +/- 3% | ||
| Maximum output current (A) | 90 |
| 2 | |
| Minimum output current (A) | 0 |
| 0 | |
| Maximum output power (W) | 450 | 24 | ||
| Input voltage range (V) | 85 – 265 |
| ||
| Input current range (A) | 6.8A@100VAC |
| ||
|
|
| 3.4A@200VAC |
| |
| Inrush current (A) | 25A@100VAC |
| ||
|
|
| 50A@200VAC |
| |
| Frequency (Hz) | 47 ~ | 63 |
| |
| Operating temperature (Celsius) | 40 |
| ||
| Safety |
| UL1950, |
| |
|
|
| EN60950 |
| |
| Efficiency (%) | 75 |
|
| |
| Max power input (W) | 632 |
| ||
| P.S Heat Dissipation (W) | 158 |
| ||
| Heat Dissipation (BTU) | 2156 |
| ||
|
|
|
|
|
|
90A DC Power Supply
Table
Parameter | Channel 1 | Channel 2 |
Nominal output voltage (V) | 5 | 12.3 |
Output voltage range (V) | 5 +/- 5% | 12.3 +/- 3% |
Maximum output current (A) | 90 | 2 |
Minimum output current (A) | 0 | 0 |
Maximum output power (W) | 450 | 24 |