Connecting to Network Devices
Connecting the The CoreBuilder 7000 family ATM switch can be configured via the LMA Control Terminal using the Administration Console terminal (VT100) or terminal emulator
(Windows). To connect a terminal to the CoreBuilder 7000 family ATM switch control port:
1Prepare an
2Configure the terminal: 19200 baud, 8 data bits, 1 stop bit, no parity, xon/xoff flow control.
3Push the DCE side of the cable onto the Control port of the switch module and screw it into place.
4Connect the other end of the cable to the terminal.
In case you have installed a redundant switch unit, it is sufficient to connect the
Connecting to the The Ethernet port is used for connecting directly to a Transcend NMS Ethernet Port terminal for management purposes.
In case you have installed a redundant switch module, its Ethernet port must also be connected directly to the Transcend NMS terminal.
Another way of connecting the Ethernet port to an
Connecting to the This section describes how to connect the CoreBuilder 7000 family ATM Power Source switch to the power source.
Selecting a Power Cord
The following power cords and accessories are supplied with the unit:
1 or 2 power cord(s) (2.5 meters each)
1 strain relief bracket per power cord
3 screws, M3 x 8 Phillips
The power cord supplied with the unit can be used with loads of up to 5 Amps AC.