Loading Software

Loading Software and Configuration Data by Batch Utilities 6-29

 

(1) SYS:\ (3) LOA: \(1) STS

 

The download status is displayed as follows:

 

Load process completed successfully.

 

The status will be success only if all the files were successfully loaded. In

 

case of failure to load a file, the “load all” process will be stopped

 

without continuing to the next file, a failure indication is displayed, and

 

the display status option will display the error message:

 

General Error occurred while loading

 

 

Loading Software

This section describes an alternative to the method of the previous

and Configuration

section: RS-232 batch-file utilities you can use to download and upload

Data by Batch

the executable software and the system configuration parameters for the

Utilities

CoreBuilder 7000 family ATM switch to an external disk via the RS-232

 

service port. It contains the following topics:

 

Batch Upload/Download Utilities

 

Batch Downgrade Utilities

 

￿Running a Batch File

 

Returning to Operational Mode

Batch

Upload/Download

Utilities

This ability allows you to easily restore the configuration to a switch which has failed or to configure a new switch with a standard configuration stored on disk.

The utility is performed by running the appropriate batch file via the RS-232 service port.

Table 6-5 shows the utilities and the batch file names.

Table 6-5Utilities for Upload/Download

Utility

Batch file name

 

 

General flash utility

fls_utl.bat

Format all configuration parameters groups in flash

cfgfrmat.bat

memory according to the mapping of version 4.0

 

Upload all configuration parameters groups from the

cfg_upld.bat

switch engine flash memory to PC file

 