Storing and Retrieving Configuration Parameters
read from the flash memory. The CoreBuilder 7000 assumes that the user wants to reboot the switch as soon as possible to activate the new configuration parameters. Therefore, subsequent to a configuration download, all LMA and SNMP set operations are blocked until the next reboot – except for the configuration upload/download and reboot operations.
It is recommended, therefore, to perform a configuration download only when you are ready to reboot and activate the new parameters.
Cards should not be “hot swapped” after a configuration download until after the next reboot.
Uploading the To store (upload) the configuration of a card installed in the CoreBuilder Configuration of a chassis from flash memory to disk, first make sure that the switch is
Card connected to the TFTP server and that it is in
1Perform the LMA menu command:
(1)SYS\ (3) LOA \(6) TCU
2The LMA automatically presents you with a list of the installed cards whose configuration you can upload to disk, for example:
Module Types: |
|
1<Switch | module 7000> |
2<Slot 3 | - 7600> |
3<Slot 4 | - 7600> |
4<Slot 5 | - 7400> |
5<Slot 6 | - 7200> |
Select Module: 1
Select the appropriate card from the
3The types of configuration data you can upload are displayed as follows.
File Types: 1<All>
2<Box Profile> 3<ATM Addresses> 4<PNNI Configuration> 5<LANE Security> 6<PVC Connections> 7<LECS Topology> 8<LECS Order List>