3Com IP Phones 125
3Click the Add button.
4Enter the IP address for the phone you want to monitor.
To specify multiple phones at once, enter the IP address and netmask for the set of phones you want to monitor.
5Click OK.
The phone or set of phones is added to the QOS Monitored Endpoints page.
The default settings are set automatically when a new entry is created. Click on an individual setting to change it.
6Repeat steps 3 - 5 to specify additional phones.
3Com IP Phones The statistics being recorded at the end of every call for each monitored 3Com IP phone are:
■SIP Call ID
■Codec Sample Size
■Codec Type
■Device Type
■Computed Mean Opinion Score
■Jitter
■Packet Loss
■Round Trip Delay
■Call Start Time
■Call End Time
■Caller Extension and IP address
■Called Party Extension and IP address
Configuring No configuration is necessary on individual 3Com IP phones. The settings 3Com IP Phones configured in the previous sections, Setting QoS Monitoring Parameters
and Specifying Phones for QoS Monitoring, are relayed to the phones automatically and generate statistics based on the thresholds configured.