Upgrading VCX Server Software from 7.0 to 7.1

89

If the Clear Replication Errors option is greyed out, make sure the Replication Settings tab is populated.

You can only delete replication errors on regional offices, not on branch offices.

3Stop Tomcat on the region 1 and 2 VCX call processing server.

a From the EMS client explorer tree, for the region 1 VCX call processing server, click 3Com VCX IP Telephony Server.

b Right-click3Com VCX IP Telephony Server, select Web Provisioning, and then click Disable Web Provisioning.

c From the EMS client explorer tree, for the region 2 VCX call processing server, click 3Com VCX IP Telephony Server.

d Right-click3Com VCX IP Telephony Server, select Web Provisioning, and then click Disable Web Provisioning.

4Stop replication between the region 1 and 2 VCX data servers.

a From the EMS client explorer tree, for the region 1 VCX data server, click 3Com VCX IP Telephony Server.

b Right-click3Com VCX IP Telephony Server, select Database Replication, and then click Drop Replication.

5Upgrade the region 1 VCX data server.

a From the EMS client explorer tree, for the region 1 VCX data server, click 3Com VCX IP Telephony Server.

b From the right-hand of the pane, click the Planned Upgrades tab. For each of these fields, the default setting is None Planned.

c Double-click the Planned System Upgrade field and click the vcx-dataserver-<version>.tarfile from the drop-down menu.

d Click Save all to commit the filename to the database.

Once an upgrade file has been selected, the file must be transferred to the server.

eTo transfer the file to the server, from the VCX data server 3Com VCX IP Telephony Server right-click menu, click Transfer Upgrade Images and then click Transfer System Upgrade File.

These options are only available is a file has been selected for upgrade. The file is SFTP'd to the server, using the SFTP credentials in the SSH/SFTP Settings tab.

Now the upgrade file needs to be installed.