Function table

Meaning & Purpose

f8 4

When the display is a stable value, the scale accumulates the data

 

automatically. The next accumulation can be performed after the

 

display returns to near-zero.

 

Used for recording the number and mass of articles removed from the

 

pan. (Put the articles on the pan. Press the

 

switch at each

 

TARE

 

removal.)

 

 

 

 

 

 

f8 5

At each finish of the full/dribble batch function, the scale accumulates

 

the data automatically.

 

Used for packaging articles like a powder, it is used for recording the

 

bag number and total mass.

 

 

 

 

10.1 Preparation (Setting Parameters)

Step

1

Turn off the display.

 

 

Press the

 

 

 

switch while the

 

 

switch is

 

 

ON/OFF

ZERO

 

 

pressed and held. The function table is displayed.

Step

2

Press the

 

switch to display an item of the

ENTER

 

 

accumulation function ( f8 ).

Step

3

Select a parameter of the accumulation function ( f8 1

 

 

~ f8 4 ) with the ^ switch.

Step

4

Press the

 

 

switch to store the new parameter.

 

ENTER

 

 

Press the F switch and the

 

 

switch to exit from

 

 

ENTER

 

 

the function table. Then the scale displays the weighing

 

 

mode.

HV-G Instruction Manual Page 26

Page 27
Image 27
A&D HV-G Series instruction manual Preparation Setting Parameters