Manuals
/
Brands
/
Baby
/
Building Set
/
A&D
/
Baby
/
Building Set
A&D
HV-G Series instruction manual
1
1
69
69
Download
69 pages, 1.67 Mb
H
H
V
V
-
-
G
G
S
S
e
e
r
r
i
i
e
e
s
s
P
P
l
l
a
a
t
t
f
f
o
o
r
r
m
m
S
S
c
c
a
a
l
l
e
e
s
s
Instruction Manual
Contents
Main
Contents
Page
1 Compliance
1.1 Compliance with FCC rules
2 Outline and Features
Page
3.1 Accessories and Options list
Accessories for HV-G series
Page
4 Caution
4.1 Precautions for Installing the Scale
4.2 Precautions for Operating the Scale
4.3 Precautions for Storing the Scale
5 Installing the Scale
5.1 Installing the Batteries for Type L
Page
6.1 Display and Symbols
Page
6.2 Switches
Page
7 Basic Operation
7.1 Turning the Scale On/Off & Basic Weighing 7.1.1 Type V or Type L with AC adaptor
7.1.2 Type L with Batteries
7.2.1 Semi-Automatic Tare (Input by Weighing)
7.2 Tare (and Net Display)
7.2.2 Preset Tare (Digital Input of Known Tare)
7.3 Weighing Range
Weighing Range
Page
8 Counting Mode
8.1 Storing a Unit Mass
8.2 Counting the number of articles
9 Percentage Mode
9.1 Storing a 100% Mass
9.2 Reading Percentage
10 Accumulation Function
Caution
10.1 Preparation (Setting Parameters)
10.2 Operation and Performance (Examples)
Example 1
Example 2
11 Comparator Function
Comparator Sign
Comparison Condition
11.1 Preparation (Setting Parameters)
Page
11.2 Operation and Performance (Examples)
Example 1
Case
Example 2
Case
12 Full/Dribble Batch Function
Caution
12.1 Preparation (Setting Parameters)
Page
13 Simple Batch Function
Comparison Condition
Parameter List and Word Definition
13.1 Preparation (Setting Parameters)
13.2 Operation and Performance (Examples)
14 Calibration (Adjusting the Scale)
Caution
14.1 The Gravity Acceleration Table
14.2 The Complete Calibration Procedure 14.2.1 Gravity Acceleration Correction
14.2.2 Preparation
14.2.3 Calibration of the Zero Point
14.2.4 Span Calibration
15 The Function Table
15.1 The Procedure for Setting Parameters
15.2 Parameter List
The type L scale is turned off after 5 minutes of no operation, when displaying zero.
Selects the method of changing the weighing range
Transmission rate of the serial interface (RS-232C/ 422/485).
Mode selection for the serial interface (RS-232C/ 422/485).
The condition of the buzzer on option OP-03 by comparator function or full/dribble batch function.
The condition of the accumulator
The printing condition when using option OP-06 for type V.
The details of the full/dribble batch function (
)
Address for RS-422 / RS-485 for option OP-04
Page
16 RS-232C Serial Data Interface
16.1 Data Format
Bit Format
Format 1
Format 2
Caution
16.2 Stream Mode
16.2.1 Preparation and Performance (Examples)
16.3 Command Mode
16.3.1 Command List
Selects the mode and unit. This is the same as the
The current weighing data is output.
The current mass value is set to the zero point.
Page
Page
16.4 Preparation (Setting Parameters)
17 Options
17.1 RS-232C / Relay output / Buzzer (OP-03)
Installing OP-03
17.2 RS-422 / RS-485 / Relay output (OP-04)
Page
17.2.1 Communication Format
Bit format
Selects the mode and unit. This is same as the
17.2.2 Command List
Data output
Zero
Tare
Caution The lower limit value must be less than the upper limit value.
Cancel of tare
Preset tare
Page
17.3 Internal Printer for Type V (OP-06)
Specification
Consumables
Operation and Print Samples
Installation of OP-06
Installation Method
Page
18 Specifications
HV-G series
Page
Page
19 Maintenance
19.1 Repair
19.2 Check Points Before Calling Maintenance