Acer Altos G610 manual Parameter, Description, Option, Emergency Management

Models: Altos G610

1 156
Download 156 pages 29.16 Kb
Page 121
Image 121
Emergency Management

 

 

111

 

 

 

Parameter

Description

Option

 

 

 

Remote Console

This parameter allows you to set the phone

User input

Phone No.

number of the RDM manager station that

 

 

the RDM module must dial once RDM is

 

 

activated and the Remote Console is

 

 

enabled. To set, simply highlight the

 

 

parameter and enter the Remote Console

 

 

phone number.

 

 

If the remote console phone number is

 

 

using an (X) line, then you must enter six

 

 

commas (,) after the phone number and

 

 

before the extension number, if any.

 

 

When entering the extension number, we

 

 

recommend that you insert a comma after

 

 

each number. The commas specify delay.

 

 

If this parameter is left blank, the Remote

 

 

Console calling function is disregarded.

 

Dial Out Retry

This parameter lets you specify the

Times

maximum number of times the RDM server

 

must retry to connect to the RDM manager

 

station once the server fails and RDM is

 

activated. If the server has completed the

 

specified number of tries and the

 

connection still fails, the server bypasses

 

RDM and goes into normal mode.

2

4

8

Infinite

Emergency Management

RDM Work

When detecting system failure, the RDM

Mode

module will take some actions according to

 

the enabled mode.

 

Waiting: Page and wait for the RDM

 

station to call in

 

Reboot: Page, then reboot

 

Disabled: No action

 

Note: If Waiting is selected, a password

 

consisting of at least three alphanumeric

 

characters must be set.

Disabled

Waiting

Reboot

Waiting Mode

Prevents unauthorized access to the server

User input

Password

 

 

 

 

 

Page 121
Image 121
Acer Altos G610 manual Parameter, Description, Option, Emergency Management