5.3 ADJUSTING THE ROOM SET POINT
The room set point is the target room temperature. It can be adjusted
between 32°F and 120°F (0°C and 48.9°C). Note that the temperature
curve must be turned off to adjust this value.
The set point can quickly be accessed by pressing the shortcut key
(note that the set point will not be accessible this way if the temperature
curve is turned on, see below to deactivate the temperature curve).
Select the "6.Room Set Point"
function from the main menu using
the navigation buttons then press
the right-arrow key. The current set
point is displayed, as well as the on/
off state of the temperature curve.
If the temperature curve is OFF,
the set point flashes on the display.
Use the adjustment buttons to
adjust the room set point to the
desired value.
If the temperature curve is ON, the
set point, as determined by the
temperature curve, is displayed.
Press the down-arrow key and
scroll the menu until "Curve stat"
status flashes on the display. Press
to turn off the temperature
curve then follow the procedure
above to adjust the set point.
Room Temperature
Set Point: 80.0°F
Curve stat Off
Day: 1
Temp: 60.0°F
Day: 10
Temp: 75.0°F
(...)
Curve stat Off
Main Menu