40
PP-32
KOOLMASTER PP-32 REV.01
Relay 31 Off(1)
Relay 32 Off(1)
On Time 15 sec
Off Time 120 sec
Ventilation Stage
Relay Assignement
3. Stage 1a
4. Stage 2a
Set the function to "17. Fan Settings" from the main menu. Note
that this menu is available only in the installer mode (see sec.
5.14.2).
Press the right-arrow key once again to select the "1. Relays" menu.
Select the stage that needs to be
adjusted by using the navigation
buttons then press the right-arrow
key (the letter standing beside fan
stages 1-4 represents the selected
program, when applicable).
Press the down-arrow key and
scroll all relays until the On-Time
display is reached.
Use the adjustment buttons to adjust the On-Time to the desired
value.
Press the down-arrow key once again and use the adjustment
buttons to set the Off-Time to the desired value.
Press the left-arrow key to exit this menu.