85
PP-32
KOOLMASTER PP-32 REV.01
RH set point % 65
Mist shutoff % Off
Heater On time Off
Heater Off time 0
full On-Time when the humidity is at or above RH Set Point + 10% as
shown below. The cycle time can be adjusted from 0 to 900 seconds.
Set the dipswitch #6 to ON to use this function.
Set the function to "18.RH Compensation" from the main menu
using the navigation buttons then press the right-arrow key. Note
that this menu only appears if the relative humidity sensor has been
enabled during the installation setup (see sec. 5.14.3).
Use the navigation buttons in order to select the "Heater On time"
display. Note that this menu only appears if dipswitch #6 is turned
ON.
Use the adjustment buttons to set
the Heater's On-Time to the desired
value.
Press the down-arrow key once to
select the "Heater Off time" display.
Use the adjustment buttons to set the Heater's Off-Time to the
desired value.