46
PP-32
KOOLMASTER PP-32 REV.01
5.11.1 Adjusting Clock Output Start and Stop Times
Set the function to "11.Clock Times" from the main menu using the
navigation buttons then press the right-arrow key. This menu is only
available if clock outputs have been enabled in the installation setup
(see sec. 5.14.3).
Press the right-arrow key once
again to select the "1.Start/Stop"
menu.
Use the navigation buttons to select
the desired clock output. Press the
right-arrow key.
If you have chosen Clock 1 or Clock
2, select the desired program use
the arrow keys to select the proper
program then press the right-arrow
key.
Use the arrow keys to select the first
start time

(On Time 1)

of the se-
lected clock output.
Use the adjustment buttons to adjust the first start time

(On Time 1)

.
Press the down-arrow key. The first off time of the selected clock
flashes on the display

(Off Time 1)

.
Use the adjustment buttons to set the first off time to the desired
value.
Proceed in similar fashion to adjust all 10 start and stop times of all
clock outputs.
If all 10 start and stop times are not needed, set the start and
stop times of unused cycles to the same value (any value except
for 12:00AM). When all start and stop times are set to
12:00AM, the output runs continuously, 24h.
Clock Time
Start / Stop
1. Clock 1
2. Clock 2
Clock Time
Start / Stop
1. Program 1
2. Program 2
Clock 1 Program 1
Animal Age: 1
On 1 8:00A (1)
Off 1 8:30A (1)