48
PP-32
KOOLMASTER PP-32 REV.01
5.12 HISTORY

5.12.1 Resetting Histories

The controller automatically resets all sensor histories when the animal
age goes from "

Off

" to "

1day

". Note that this reset doen't clear the
Alarm Log history.
The following procedure shows how to clear all histories without having
to change the animal age.
Set the function to "12.Animal Age" from the main menu using the
navigation buttons.
Press the down-arrow key once to select the "Clear All?" menu.
If the following step is performed from the INSTALLER
mode, the Alarm Log will be lost. If it is performed from
the USER mode, the Alarm history will not be reset. Refer
to section 5.14.3 to select the proper mode.
Press to select

Yes

. The
answer is validated after a 10
second delay. The display then
returns to

"No"

. Histories are now
cleared.

5.12.2 Average Temperature History

The controller has an history in which the minimum and maximum
average temperature readings for the past 60 days are logged in.
Set the function to "2. Average Temp." from the main menu using
the navigation buttons then press the right-arrow key. The current
average room temperature is displayed.
Press the down-arrow key to scroll
the menus. The minimum

(T°L)

and
maximum

(T°H)

temperatures for
the past 60 days are displayed.
5 days ago
T°L 72.3 T°H 74.0
6 days ago
T°L 72.0 T°H 74.3
Animal Age Off
Clear All? No
!
WARNING