27
PP-32
KOOLMASTER PP-32 REV.01
Open Time 30sec
Close Time 30sec
Off Time 60sec
Off Time: once the vent doors have opened or closed (depending on the
situation), they then stop operating during the Off time delay. The Off
Time delay ranges from 0 to 900 seconds.
If the pressure has not reached the desired value after the Off Time, the
cycle starts again, up until the pressure goes back into the normal range.
Select "8.Vents/Static P" from the main menu using the navigation
buttons then press the right-arrow key. Note that this menu is only
available if the static pressure sensor has been enabled during the
installation setup (see sec 5.14.3).
Press the right-arrow key to select the "1.Set Points" menu.
Press the down-arrow key in order
to select the Open Time then use
the adjustment buttons to set the
opening time to the desired value.
Press the down-arrow key. The Close Time flashes on the display.
Use the adjustment buttons to set the Close Time to the desired value.
Press the down-arrow key once again. The Off Time flashes on the
display. Use the adjustment buttons to set the Off Time to the
desired value.
VENT DOORS TIMER
ON
OPEN / CLOSE
TIMES
OFF
TIME
OFF