35
PP-32
KOOLMASTER PP-32 REV.01
5.6.3 Adjusting Curtain's Operating Times

This function is only used if the curtain operates in timer mode.

The curtain's operating time is the time during which the curtain opens
when a new tunnel fan stage is activated or closes when a tunnel fan
stage is deactivated. This value needs to be adjusted for each tunnel fan
stage. In addition, the user must set the maximum curtain's running
time. The sum of all running times cannot exceed this value.
Operating times range from 0 seconds to 15 minutes, in increment of
5 seconds. Select "Off" if you do not want the curtain to open when the
start temperature of a certain stage is reached.
Select "9.Tunnel Curtain" from the main menu using the navigation
buttons then press the right-arrow key. Note that this menu is only
available if the tunnel curtain has been enabled during the installation
setup (see sec 5.14.3).
Press the right-arrow key once to select "1.Set Points" menu.
Press the down-arrow key in order
to select the "Total Run Time"
function then use the adjustment
buttons to set the curtain's maxi-
mum running time. This menu only
appears if the tunnel curtain oper-
ates in timer mode (see sec 5.14.3).
Press the down-arrow key once. The
first tunnel fan stage is selected. Set
the curtain's opening time for that
stage. When the start temperature
of this stage is reached, the curtain
will open during this delay.
Proceed in similar fashion to set all curtain running times for each
tunnel stage below. Remember that the sum of all running times
cannot exceed the "Total Run Time" value.
Tunnel Curtain
Tunnel Stage # 5
Min. Animal age 1
Open/Clo Time mm:ss
Total Run Time 2:00
Stage 5 0:30
Stage 6 0:30
Stage 7 0:30
Stage 8 0:30