66
PP-32
KOOLMASTER PP-32 REV.01

5.14.4 Sensor Assignment

5.14.4.1 Assigning Sensors to the Room T° and Fan Stages
The controller uses the average reading of activated sensors to calculate
the room temperature. Fan stages use this temperature to operate.
The selection of sensors that are used to determine the average room
temperature differs depending on the selected program. Therefore, the
user must make a separate sensor assignment for each program in use.
Note also that sensor assignment can only be done from the installer
mode (see sec. 5.14.2).
Set the function to "17.Fan
Settings" from the main menu
using the navigation buttons. Note
that this menu is only available in
the installer mode (see sec. 5.14.2).
Press the down-arrow key once to
select "2.Sensors" menu then press
the right-arrow key.
Press the right-arrow key once to
select "1.Program (x)" or "1.Sensor
Selection" menu (depending if many
programs are activated). Sensors
that have been activated during the
installation are displayed (see sec. 5.14.3).
Use the right and left-arrow keys to select the desired sensor. When
the item is flashing, press to activate the sensor or to
deactivate it. The selected sensors are used to calculate the aver-
age room temperature into the selected program.
Proceed in similar fashion to activate the proper sensors for each
program. Refer to sec. 5.2 to select another program.
Ventilation Stage
Settings
2. Sensors
Program (a) Sensors
12345678
√√√
Sensor Settings
1. Program (a)
2. Auxiliary 1