49
PP-32
KOOLMASTER PP-32 REV.01
5.12.3 Individual Temperature Sensors History
The controller has an history in which the minimum and maximum
temperature readings of each sensor, for the past 10 days, are logged in.
Set the function to "3.Temp.
Sensors" from the main menu using
the navigation buttons then press
the right-arrow key. Sensors'
temperature readings are displayed.
Press the down-arrow key to scroll the display. Sensors' Hi and Lo
temperature readings are displayed for the past 10 days.
5.12.4 Outside Temperature Sensor History
The controller has an history in which the minimum and maximum
temperature readings of the outside temperature sensor, for the past 10
days, are logged in.
Set the function to "3.Temp. Sensors" from the main menu using the
navigation buttons then press the right-arrow key. Sensors' tempera-
ture readings are displayed.
Press the down-arrow key to scroll
the display. The outside temperature
sensors' Hi and Lo temperature
readings

(OutL and OutH)

are dis-
played for the past 10 days.
5.12.5 Relative Humidity History
The controller has an history in which the minimum and maximum
humidity readings for the past 10 days are logged in.
Set the function to "4.R. Humidity"
from the main menu using the
navigation buttons then press the
right-arrow key. The current
humidity level is displayed. This
menu is only accessible if a humidity
sensor has been installed (see sec. 5.14.3).
2 days ago
T°1L 69.2 T°1H 75.4
T°2L 70.3 T°2H 74.0
T°3L 69.3 T°3H 74.2
2 days ago
T°1L 69.2 T°1H 75.4
T°2L 70.3 T°2H 74.0
OutL 79.3 OutH 84.7
Min/Max Recorded
RH L 81 RH H 84
Yesterday
RH L 79 RH H 90