Actiontec electronic IS560LH Automatic Disconnect Delay, DTMF Dialing Speed, Escape Guard Time

Models: IS560LH

1 77
Download 77 pages 15.67 Kb
Page 68
Image 68
Automatic Disconnect Delay

S10

Automatic Disconnect Delay

Range:

1-254

Default:

20

Units:

0.1 seconds

This register sets the length of time, in tenths of a second, that the modem waits before hanging up after a loss of carrier. This allows for a temporary carrier loss without causing the local modem to disconnect. The actual interval the modem waits before disconnecting is the value in register S10.

S11

DTMF Dialing Speed

Range:

50-150

Default:

95

Units:

0.001 seconds

This register determines the dialing speed which is prefixed for each country.

S12

Escape Guard Time

Range:

0-255

Default:

50

Units:

0.02 seconds

This register sets the value (in 20 ms increments) for the required pause after the escape sequence (default 1s).

S14

General Bit Mapped Options Status

Indicates the status of command options. Only bit 2 and bit 5 are used, read only.

Bit 3 Result codes (Vn) 0 = Numeric (V0)

1 = Verbose (Vl) (Default)

Bit 6 Pulse dial PPS selection (&Pn)

0 = 10 PPS (&p0, &p1) (Default)

1 = 20 PPS (&p2)

Default: 8 (00001000b)

68

Page 68
Image 68
Actiontec electronic IS560LH user manual Automatic Disconnect Delay, DTMF Dialing Speed, Escape Guard Time, seconds