Chapter 4. Application Configuration

DTR Options

Ignore DTR

Flow Control

Hardware Flow

Protocol

Fallback

The Express XRT can be reset to the factory default settings by set- ting switch 2 to the Off (up) position. See the section Verify Switch Settings on page 5 for more information.

Profile Configurations

Some common configurations are preset in the Express XRT soft- ware as profiles. Most Internet service providers supporting ISDN also support PPP protocol. If connecting to an Internet ser- vice provider using one B-channel, select Factory: PPP 64k (Inter- net), which sets the protocol to PPP. If arrangements have been made with the Internet service provider to use two B-channels, se- lect Factory: Multilink PPP 128k (Internet), which uses multilink PPP protocol.

Loading a factory profile has no effect on any ISDN Phone Num- ber(s) or Switch Type settings already configured. The settings that are altered when applying a profile are shown as follows:

Factory: PPP 64k (Internet)

Call Type

Data 64kbps

Auto Answer

Enabled

DTR Options

Ignore DTR

Flow Control

Hardware

Protocol Type

PPP

PPP Mode

Single-link PPP

Factory: Multilink PPP 128k (Internet)

Call Type

Data 64kbps

Auto Answer

Enabled

DTR Options

Ignore DTR

Flow Control

Hardware

Protocol Type

PPP

PPP Mode

Multilink PPP

38